Related Experiment Video
Updated: Sep 4, 2025

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Which interventions may improve bracing compliance in adolescent idiopathic scoliosis? A systematic review and
Xue Li1, Zhaohua Huo1, Zongshan Hu2
1School of Public Health and Primary Care, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China.
Abstract:
This review aimed to systematically review and meta-analyze the effects of interventions in improving bracing compliance among adolescent idiopathic scoliosis (AIS) patients. Eight databases were searched from their inception to April 2022. The eligibility criteria included controlled studies that used any type of intervention to enhance bracing compliance in braced AIS patients. Two researchers independently screened articles and extracted data based on the PICO (participant, intervention, comparator, and outcome) framework. Quality appraisal of included studies was performed using GRADE (overall assessment), and the risk of bias was assessed with Cochrane RoB Tool 2 for randomized controlled trials (RCT) and ROBINS-I for non-RCT studies. The primary outcome was bracing compliance and secondary outcomes included Cobb Angle and measurements for quality of life. Six eligible studies involving 523 participants were included. All studies were evaluated as low or very low quality with a high risk of bias. Four types of interventions were identified, including sensor monitoring (n = 2, RCTs), auto-adjusted brace (n = 1, RCT), more intensive or collaborated medical care (n = 2), and psychosocial intervention (n = 1). A meta-analysis of 215 patients from the three RCTs suggested that the compliance-enhancing intervention group had 2.92 more bracing hours per day than the usual care control (95%CI [1.12, 4.72], P = 0.001). In subgroup analysis, sensor monitoring significantly improved bracing wearing quantity compared to usual care (3.47 hours/day, 95%CI [1.48, 5.47], P = 0.001), while other aforementioned interventions did not show a significant superiority. Compliance-enhancing interventions may be favorable in preventing curve progression and promoting quality of life, but the improvements cannot be clarified according to limited evidence. In conclusion, although the results of this study suggested that sensor monitoring may be the most promising approach, limited high-quality evidence precludes reliable conclusions. Future well-designed RCTs are required to confirm the actual benefit of compliance-improving interventions in clinical practice.
More Related Videos
08:08Cell-based Assay Protocol for the Prognostic Prediction of Idiopathic Scoliosis Using Cellular Dielectric Spectroscopy
Published on: October 16, 2013
06:28Biomechanical Changes Related to Low Back Pain: An Innovative Tool for Movement Pattern Assessment and Treatment Evaluation in Rehabilitation
Published on: December 13, 2024
Related Concept Videos
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Community Based Intervention
Foundations of Community Mental Health Programs
Central to the success of community-based interventions is the...