Improved Passive Gamma Emission Tomography image quality in the central region of spent nuclear fuel
Related Experiment Video
Updated: Sep 4, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Riina Virta1,2, Tatiana A Bubba3, Mikael Moring4
1Helsinki Institute of Physics, University of Helsinki, Helsinki, Finland. riina.virta@helsinki.fi.
Abstract:
Reliable non-destructive methods for verifying spent nuclear fuel are essential to draw credible nuclear safeguards conclusions from spent fuel. In Finland, spent fuel items are verified prior to the soon starting disposal in a geological repository with Passive Gamma Emission Tomography (PGET), a uniquely accurate method capable of rod-level detection of missing active material. The PGET device consists of two highly collimated detector banks, collecting gamma emission data from a 360° rotation around a fuel assembly. 2D cross-sectional activity and attenuation images are simultaneously computed. We present methods for improving reconstructed image quality in the central parts of the fuel. The results are based on data collected from 2017 to 2021 at the Finnish nuclear power plants with 10 fuel assembly types of varying characteristics, for example burnups from 5.7 to 55 GWd/tU and cooling times from 1.9 to 37 years. Data is acquired in different gamma energy windows, capturing the peaks of Cs-137 (at 662 keV) and Eu-154 (at 1274 keV), abundant isotopes in long-cooled spent nuclear fuel. Data from these gamma energy windows at well-chosen angles are used for higher-quality images, resulting in more accurate detection of empty rod positions. The method is shown to detect partial diversion of nuclear material also in the axial direction, demonstrated with a novel measurement series scanning over the edge of partial-length rods.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Nuclear Transmutation