"Low Dose MR" Dixon Technique for Imaging FDG PET-MR Lymphoma
Musa Ali Mufti1, Robert Matthews2, Ezemonye Madu3
1Department of Radiology, Stonybrook University Hospital, New York, New York, United States.
Abstract:
Introduction Hybrid PET-MR is a relatively new imaging modality with its major strength being the MR component offering superior soft tissue contrast. While PET/MRI offers the inherent advantage of reduced radiation dose, it has been shown to result in a markedly prolonged examination time becoming a challenge in children and sick patients. "Low dose MRI" is a term used in the nuclear medicine community to describe fast acquired PET-MR scan protocols that rely heavily on PET images for diagnosis. In this study, we sought to determine if the Dixon sequences obtained for attenuation correction could be used as a diagnostic sequence for interpreting PET-MRI lymphoma cases, potentially reducing scan time. Materials and Methods We retrospectively identified 40 patients who underwent 88 FDG PET-MR body imaging studies for staging or restaging lymphoma. A radiologist and nuclear medicine physician initially reviewed top of the head to mid thigh PET images, attenuation correction coronal Dixon MRI sequences, and PET-MR fusion with Dixon sequence. The same physicians reviewed the PET images, multi-sequence MR including the attenuation correction Dixon, and multi-sequence PET-MR fusion images The lesions were further characterized based on their imaging characteristics, size, SUVmax, and malignant potency. A consensus read followed. Results All patients were adults with an average study age of 43.8 years. Our study consisted of 40 females and 48 males out of which 7 were for staging and 81 were for re-staging. All patients had systemic lymphoma. Thirty-seven of the studies had active lymph nodes on Dixon PET-MR that agreed with multi-sequence PET-MR which identified 33 positive cases (89.1%) having an average SUV 10.2 ± 7.74 SD. Four Dixon PET-MR cases did not detect lesions, with an average SUV 2.3 ± 0.55 SD, which was read as minimal residual activity. Multi-sequence MR identified 11 patients with enlarged lymph nodes without FDG uptake, which were not seen on Dixon MR. All 5 studies with bones lesions were detected by Dixon PET-MR as well as 2 soft tissue organ lesions. Multi-sequence MR identified 1 patient with non-active, healed bone lesion. Fifty-five of these studies were true negatives. Compared to multi-sequence PET-MR, Dixon PET-MR demonstrated 89.2% sensitivity, 100% specificity with no false positive studies. Conclusion The present study investigated the diagnostic potential of a fast protocol for integrated PET/MRI used for dedicated tumor staging of patients with lymphoma. In this retrospective study, Dixon PET-MR was shown to be sensitive and specific compared to multi-sequence PET-MR in the detection of lymphoma. The low number of these cases not detected had minimally active lymph nodes that resolved on subsequent imaging and probably were not clinically important.
Insights
Fast PET-MR protocols using Dixon sequences show high sensitivity and specificity for detecting lymphoma, potentially reducing scan times in patients. This approach aids in staging and restaging lymphoma effectively.
Area of Science:
- Radiology and Nuclear Medicine
- Medical Imaging Technology
- Oncology
Background:
- Hybrid PET-MR imaging offers superior soft tissue contrast but often involves prolonged scan times, posing challenges for pediatric and critically ill patients.
- "Low dose MRI" protocols in nuclear medicine utilize fast PET-MR scans, relying on PET for diagnosis to shorten examination duration.
- Dixon sequences are primarily used for attenuation correction in PET-MR but may hold diagnostic potential.
Purpose of the Study:
- To evaluate the diagnostic utility of Dixon sequences, acquired for attenuation correction, as a standalone diagnostic tool in PET-MR lymphoma imaging.
- To determine if Dixon sequences can replace multi-sequence MRI, thereby reducing overall PET-MR examination time for lymphoma staging and restaging.
- To assess the sensitivity and specificity of Dixon PET-MR compared to conventional multi-sequence PET-MR for lymphoma detection.
Main Methods:
- Retrospective analysis of 40 patients with lymphoma who underwent 18F-FDG PET-MR body imaging.
- Initial review by a radiologist and nuclear medicine physician included PET images, coronal Dixon MRI sequences (for attenuation correction), and PET-MR fusion with Dixon.
- Subsequent review involved multi-sequence MR (including Dixon) and multi-sequence PET-MR fusion images, with lesion characterization based on imaging features, size, SUVmax, and malignancy potential.
Main Results:
- Dixon PET-MR identified active lymph nodes in 37 studies, agreeing with multi-sequence PET-MR in 33 positive cases (89.1%) with an average SUVmax of 10.2.
- Four cases with minimal residual activity (average SUV 2.3) were missed by Dixon PET-MR but detected by multi-sequence imaging.
- Dixon PET-MR demonstrated 89.2% sensitivity and 100% specificity compared to multi-sequence PET-MR, detecting all bone lesions and 2 soft tissue lesions.
Conclusions:
- Fast PET-MR protocols utilizing Dixon sequences show significant diagnostic potential for lymphoma staging and restaging.
- Dixon PET-MR is a sensitive and specific imaging method for detecting lymphoma, comparable to more time-consuming multi-sequence PET-MR protocols.
- The use of Dixon sequences as a diagnostic tool in PET-MR lymphoma imaging can potentially reduce scan times without compromising diagnostic accuracy for most clinically significant findings.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...