Related Experiment Video
Updated: Sep 3, 2025

Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
Comparison of the NIO and EZIO for Resuscitative Vascular Access in the Emergency Department: A Quasi-Experimental,
Byron C Drumheller1, Matthew D Edgar1, Meghan K Tape1
1Department of Emergency Medicine, Einstein Healthcare Network, Einstein Medical Center Philadelphia, Philadelphia, PA 19141, USA.
Introduction:
Intraosseous (IO) needle insertion is a key adjunctive procedure in the care of critically ill and injured patients in a variety of settings, including the battlefield. The NIO is a new, fully disposable, single-piece, IO device with potential practical advantages under austere conditions. We sought to compare the efficacy and safety of the NIO to an established, well-studied device, the EZIO, when used for resuscitative vascular access in the emergency department (ED).
Methods:
Retrospective, single-center, quasi-experimental, before-and-after, observational cohort study performed at an urban, tertiary-care hospital ED among adult patients receiving IO access during resuscitation. The before/NIO period lasted from July 1, 2019, to May 31, 2020, and the EZIO/after period from June 1, 2020, to April 30, 2021. Patient demographics, prehospital treatment, ED presentation, characteristics and results of IO insertion(s), potential procedure-associated adverse events, and ED and hospital outcomes were abstracted from the medical record. The primary outcome, rate of first-pass success (FPS), was compared between the NIO and EZIO periods using multivariable regression after adjustment for potential confounding factors.
Results:
We enrolled 63 total patients/66 limbs (mean age 61 ± 18, 51% female), 34 patients/35 limbs during the NIO period and 29 patients/31 limbs during the EZIO period. The most common reason for IO insertion was cardiac arrest (40/63, 63%), followed by respiratory failure, trauma, and sepsis. The majority of IO insertions were performed at the proximal tibia (58/66, 88%) by senior emergency medicine residents or faculty. The overall rate of FPS was 53/66 (80%), 24/35 (69%) with the NIO compared to 29/31 (94%) with the EZIO. After multivariable modeling, the odds of FPS with the NIO vs. the EZIO was 0.19 (95% CI, 0.01-1.5, P = .16). Procedure-related adverse events were infrequent in both groups. In-hospital mortality was 45/63 (71%).
Conclusions:
We found that the NIO device was associated with a lower-than-expected rate of FPS compared to the EZIO device, although not significantly different after adjusting for between-group imbalances and considering limitations in the study design. Further, prospective research into the efficacy and safety of the NIO is needed before clinical use can be encouraged.
More Related Videos
08:21Functional Assessment of the Donor Heart During Ex Situ Perfusion: Insights from Pressure-Volume Loops and Surface Echocardiography
Published on: October 11, 2022
06:30Complete and Partial Resuscitative Endovascular Balloon Occlusion of the Aorta for Hemorrhagic Shock
Published on: May 19, 2022
Related Concept Videos
Cardiopulmonary Resuscitation III: AED Use
Cardiopulmonary Resuscitation IV: Pharmacological Management
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiac Catheterization IV: Nursing Management