In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Elastodontic Devices in Orthodontics: An In-Vitro Study on Mechanical Deformation under Loading
Vincenzo Quinzi1, Gianni Gallusi1, Elisabetta Carli2
1Department of Life, Health and Environmental Science, University of L'Aquila, 67100 L'Aquila, Italy.
Elastodontic devices (ED) show minimal plastic deformation, generally under 1.75%, indicating clinical acceptability. The Ortho-Tain device exhibited the highest compression load and lowest deformation during mechanical testing.
Area of Science:
- Dentistry
- Biomaterials Science
- Orthodontics
Background:
- Elastodontic devices (ED) are used in orthodontic treatments.
- Evaluating the mechanical properties of ED is crucial for treatment efficacy and patient safety.
Purpose of the Study:
- To assess the mechanical resistance of various elastodontic devices (ED).
- To determine maximum compression loads and plastic deformation percentages under cyclic loading.
Main Methods:
- Mechanical testing using an Instron universal machine with a 100 N load cell.
- A five-cycles test was performed on multiple ED brands, including A.M.C.O.P., HealthyStart (Ortho-Tain), and T4K™ phase 1.
- Compression load and plastic deformation were analyzed using Bluehill software.
Main Results:
- The Ortho-Tain device demonstrated the highest compression load (7.56 N) with the lowest plastic deformation (0.95%).
- All tested ED exhibited slight plastic deformation, ranging from 0.95% to 1.75%, considered clinically acceptable.
- The T4K™ phase 1 device could not complete the five-cycles test.
Conclusions:
- Elastodontic devices generally possess acceptable mechanical resistance and minimal plastic deformation.
- The Ortho-Tain device shows superior mechanical performance compared to others tested.
- Further research is recommended to evaluate ED performance after clinical use.
Related Concept Videos
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Normal Strain under Axial Loading
Residual Stresses in Bending
Plastic Deformations
Temperature Dependent Deformation