Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)
Rafał Januszek1, Wojciech Siłka2, Karol Sabatowski1
1Department of Cardiology and Cardiovascular Interventions, University Hospital, 30-688 Kraków, Poland.
Abstract:
(1) Introduction: Optical coherence tomography (OCT) intravascular imaging facilitates percutaneous coronary intervention (PCI). Software for OCT is being constantly improved, including the latest version Ultreon™ 1.0 Software (U) (Abbott Vascular, Santa Clara, CA, USA). In the current analysis, we aim to compare processing results, procedural indices as well as clinical outcomes in patients treated via PCI. This was conducted using earlier generation OCT imaging software versions (non-U) and the newest available one on the market (U). (2) Methods: The study comprised 95 subsequent and not selected patients (55 processed with U and 40 non-U). The non-U processings were transferred for evaluation by U software, while the comparison of OCT parameters, selected clinical and procedural indices was performed between groups. We further assessed clinical outcomes during the follow-up period, i.e., major adverse cardiovascular events (MACE) and predictors of stent expansion. (3) Results: We did not detect any differences in general features between either of the assessed groups at baseline. Non-U software was more often used for bare-metal stenting (p = 0.004), while PCIs in the U group demanded a greater number of stents (p = 0.03). The distal reference of external elastic lamina (EEL) diameter was greater in the non-U group (p = 0.02) with no concurrent differences in minimal (p = 0.27) and maximal (p = 0.31) stent diameter. It was also observed that MACE was more frequently observed in the non-U group (p = 0.01). Neither univariable (estimate: 0.407, 95%CI: (-3.182) - 3.998, p = 0.82) nor multivariable (estimate: 2.29, 95%CI: (-4.207) - 8.788, p = 0.5) analyses demonstrated a relationship between the type of software and stent expansion. (4) Conclusions: Improvement in the software for image acquisition and processing of OCT is not related to stent expansion. The EEL diameter is preferably used to select the distal stent diameter in newer software.
More Related Videos
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization II: Right Heart Catheterization
