Related Experiment Video
Updated: Sep 3, 2025

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Performance of Invasive Mode in Different Heated Humidification Systems With High-Flow Nasal Cannula
Gustavo A Plotnikow1,2, Dario S Villalba3, Eliana Pérez Calvo3,4
1Division of Physical Therapy and Respiratory Care, Rehabilitation Department, Intensive Care Unit, Hospital Británico de Buenos Aires, Buenos Aires, Argentina. gplotnikow@hbritanico.com.ar.
Background:
Oxygen therapy via high-flow nasal cannula generates physiologic changes that impact ventilatory variables of patients. However, we know that there are detrimental effects on airway mucosa related to inhalation of gases. The objective of this study was to evaluate the performance in terms of absolute humidity, relative humidity, and temperature of different brands of heated humidifiers and circuits in the invasive mode during the use of high-flow oxygen therapy in flows between 30 and 100 L/min.
Methods:
A prospective observational study conducted at the Sanatorio Anchorena equipment analysis laboratory; September 5 to October 20, 2019.
Results:
A statistically significant interaction was found among the programmed flows and the different combinations of devices and circuits for the delivery of absolute humidity (P < .001). An effect of flow on delivered absolute humidity was found, regardless of the equipment and circuit combination (P < .001). However, in the invasive mode, the combination of the Fisher&Paykel MR850 heated humidifier with the Medtronic-Dar circuit, the Intersurgical circuit, and the AquaVENT circuit always reached or achieved absolute humidity values > 33 mg/L, even at flows up to 100 L/min. The combination of the Flexicare FL9000 heated humidifier with the Fisher&Paykel RT202 circuit, the Fisher&Paykel Evaqua 2 circuit, the Flexicare circuit, the AquaVENT circuit, and the GGM circuit achieved similar results. The mean (SD) of absolute humidity delivered in the invasive mode (36.2 ± 5.9 mg/L) was higher compared with the noninvasive mode (26.8 ± 7.2 mg/L) ( P < .001), regardless of circuit and programmed flows.
Conclusions:
When heated humidifiers were used in the invasive mode for high-flow oxygen therapy, absolute humidity depended not only on the heated humidifiers and the combination of circuits but also on the programmed flow, especially at flows > 50 L/min. Moreover, the heated humidifiers exhibited different behaviors, in some cases inefficient, in delivering adequate humidification. However, some equipment improved performance when set to the invasive mode.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...