Related Experiment Video
Updated: Sep 3, 2025

Three-dimensional Optical-resolution Photoacoustic Microscopy
Published on: May 3, 2011
Highly Sensitive Measurement of Oxygen Concentration Based on Reflector-Enhanced Photoacoustic Spectroscopy
Shuhan Yang1, Shunda Qiao1, Xiaonan Liu1
1National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology, Harbin 150001, China.
Abstract:
Oxygen (O2) is a colorless and odorless substance, and is the most important gas in human life and industrial production. In this invited paper, a highly sensitive O2 sensor based on reflector-enhanced photoacoustic spectroscopy (PAS) is reported for the first time. A diode laser emitting at 760 nm was used as the excitation source. The diode laser beam was reflected by the adopted reflector to pass thorough the photoacoustic cell twice and further increase the optical absorption. With such enhanced absorption strategy, compared with the PAS system without the reflector, the reflector-enhanced O2-PAS sensor system had 1.85 times the signal improvement. The minimum detection limit (MDL) of such a reflector-enhanced O2-PAS sensor was experimentally determined to be 0.54%. The concentration response of this sensor was investigated when O2 with a different concentration was used. The obtained results showed it has an excellent linear concentration response. The system stability was analyzed by using Allan variance, which indicated that the MDL for such a reflector-enhanced O2-PAS sensor could be improved to 318 ppm when the integration time of this sensor system is 1560 s. Finally, the O2 concentration on the outside was continuously monitored for 24 h, indicated that this reflector-enhanced O2-PAS sensor system has an excellent measurement ability for actual applications in environmental monitoring, medical diagnostics, and other fields.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...