Related Experiment Video
Updated: Sep 3, 2025

Free Radicals in Chemical Biology: from Chemical Behavior to Biomarker Development
Published on: April 15, 2013
Identification and Quantitation of Aqueous Single- and Multianalyte Solutions of the Isomers Ethylbenzene, m-, p-,
Nicholas Post1, Florian Bender1, Fabien Josse1
1Department of Electrical and Computer Engineering, Marquette University, Milwaukee, Wisconsin 53201-1881, United States.
Abstract:
The isomer-specific detection and quantitation of m-, p-, and o-xylene and ethylbenzene, dissolved singly and as mixtures in aqueous solutions at concentrations from 100 to 1200 ppb by volume, is reported for a specifically designed polymer-plasticizer coating on a shear-horizontal surface acoustic wave (SH-SAW) device. The polystyrene-ditridecyl phthalate-blend coating was designed utilizing Hansen solubility parameters and considering the dipole moment and polarizability of the analytical targets and coating components to optimize the affinity of the sensor coating for the four chemical isomers. The two key coating sorption properties, sensitivity and response time constant, are determined by the (slightly different) dipole moments and polarizabilities of the four target analytes: as analyte dipole moment decreases, coating sensitivity increases; as analyte polarizability decreases, coating response time lengthens. Using the measured sensitivities and time constants for the targets, sensor signals were processed with exponentially weighted recursive-least-squares estimation (EW-RLSE) to identify (with near 100% accuracy) and quantify (with ± 5-7% accuracy) the isomers. This impressive performance was achieved by combining the specifically tailored, high-sensitivity coating and an SH-SAW platform (yielding a detection limit of 5 ppb for the analytes) and using the EW-RLS estimator, which estimates unknown parameters accurately even in the presence of measurement noise and for analytes with only minor differences in response. Identification of the xylene isomers is important for applications including environmental monitoring and chemical manufacturing.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
¹H NMR Signal Integration: Overview
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...