Related Experiment Video
Updated: Sep 3, 2025

Fabrication and Operation of an Oxygen Insert for Adherent Cellular Cultures
Published on: January 6, 2010
A Low-Resource Oxygen Blender Prototype for Use in Modified Bubble CPAP Circuits: Results from Design Feasibility
Andrew G Wu1, Sreyleak Luch2, Jared R Floersch3
1Division of Critical Care Medicine, Boston Children's Hospital, Boston, Massachusetts.
None:
Bubble CPAP is used in low-resource settings to support children with pneumonia. Low-cost modifications of bubble CPAP using 100% oxygen introduces the risk of hyperoxia. Our team developed a low-cost, readily constructible oxygen blender to lower the oxygen concentration. The next step in development was to test its construction among new users and ascertain three outcomes: construction time, outflow oxygen concentration, and an assessment of the user experience. Workshops were conducted in two countries. Instructions were delivered using a live demonstration, a video, and written instructions in the respective native language. Twelve volunteers participated. Average construction times were 24 minutes for the first attempt and 15 minutes for the second. The oxygen concentrations were 53-63% and 41-51% for the 5 and 10 mm entrainment ports, respectively. This novel, low-cost oxygen blender for bubble CPAP can be constructed among new users with reliable performance across devices.
More Related Videos
07:38Design and Development of a Model to Study the Effect of Supplemental Oxygen on the Cystic Fibrosis Airway Microbiome
Published on: August 3, 2021
13:59Reduced-gravity Environment Hardware Demonstrations of a Prototype Miniaturized Flow Cytometer and Companion Microfluidic Mixing Technology
Published on: November 13, 2014
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: