Bond Behavior of Steel Cords Embedded in Inorganic Mortars
Francesca Roscini1, Maurizio Guadagnini1
1Department of Civil and Structural Engineering, The University of Sheffield, Sheffield S1 3JD, UK.
Abstract:
This paper investigates the bond behavior of steel cords embedded in inorganic matrices. A series of pull-out tests were carried out on individual galvanized steel cords embedded in either a cementitious or lime-based mortar matrix and the corresponding bond-slip relationships were derived. The quality of bond between cord and mortar was found to be critically affected by the workability of the mortar and its ability to create adequate composite action along the entire embedment length of the cord. The more workable lime-based mortar was found to guarantee a better interaction with the steel cord, in terms of initial bond stiffness, maximum bond strength, and post-peak behavior. The experimentally derived bond-slip relationships were subsequently integrated in a 3D non-linear finite element framework and used to determine the constitutive relationship of a surface-based cohesive contact between cord and mortar. The cohesive bond behavior was used to conduct a series of parametric studies on cords embedded in a lime-based mortar and examine the stress development within specimens with cords of different embedment lengths and subjected to different loading conditions (i.e., pull-out and direct tension). The active 'Stress Transfer Zone' was found to be about 125 mm, while an 'Effective Transfer Radius' of approximately 3.5-4 mm was identified. The numerical investigation implemented in this paper enabled one to study key interaction properties of steel reinforced grouts and can assist the design of more effective strengthening solutions.
More Related Videos
Related Concept Videos
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Bonding and Strength of Aggregate
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Mortar Properties
Reinforced Brick Masonry
To fortify brick walls...
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...