Related Experiment Video
Updated: Sep 3, 2025

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Endotracheal Tube Size in Critically Ill Patients
Brandon I Esianor1, Benjamin R Campbell1, Jonathan D Casey2
1Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee.
Importance:
Many patients who survive critical illness are left with laryngeal functional impairment from endotracheal intubation that permanently limits their recovery and quality of life. Although the risk for laryngeal injury increases with larger endotracheal tube sizes, there are no data delineating the association of smaller endotracheal tube sizes with survival or acute recovery from critical illness.
Objective:
To determine if smaller endotracheal tubes are noninferior to larger endotracheal tubes with respect to critical illness outcomes.
Design, Setting, And Participants:
This propensity score-matched retrospective cohort study included all adult patients who underwent endotracheal intubation in the emergency department or intensive care unit and received mechanical ventilation for at least 12 hours from June 2020 to November 2020 at a single tertiary referral academic medical center.
Exposures:
Endotracheal intubation.
Main Outcomes And Measures:
Propensity score-matched analyses were performed with respect to the primary end point of 30-day all-cause in-hospital survival as well as the secondary end points of duration of invasive mechanical ventilation, length of hospital stay, mean peak inspiratory pressure, 30-day readmission, need for reintubation, and need for tracheostomy or gastrostomy tube placement.
Results:
Overall, 523 participants (64%) were men and 291 (36%) were women. Of these, 814 patients were categorized into 3 endotracheal tube groups: small for height (n = 182), appropriate for height (n = 408), and large for height (n = 224). There was not a significant difference in 30-day all-cause in-hospital survival between groups ([HR, 1.1; 95% CI, 0.7-1.7] for small vs appropriate; [HR, 1.1; 95% CI, 0.7-1.6] for large vs appropriate). Patients with small-for-height endotracheal tubes had longer intubation durations (mean difference, 32.5 hrs [95% CI, 6.4-58.6 hrs]) compared with patients with appropriate-for-height tubes.
Conclusions And Relevance:
Despite differences in intubation duration, the results of this cohort study suggest that smaller endotracheal tube sizes are not associated with impaired survival or recovery from critical illness. They support future prospective exploration of the association of smaller endotracheal tube sizes with recovery from critical illness.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...