An acute gastroenteritis outbreak associated with a contaminated water supply system, Turkey, 2018
Zeynep Özge Özgüler1, Nayak Priyakanta2, Serap Cetin Coban1
1General Directorate of Public Health, Ministry of Health of Turkey, Adnan Saygun St, Çankaya, Ankara, Turkey
Abstract:
Disruption of routine monitorization and chlorination of the water supply system during a week-long holiday led to a multi-organism gastroenteritis outbreak in a district with limited laboratory support. More than a 10-fold increase in patients with gastroenteritis was reported. Enteropathogenic Escherichia coli, Enteroaggregative E. coli, and norovirus were detected in human specimen samples. The main water tank and pipes were rusted; 13 out of the 19 water samples tested positive for total Coliform (1-920 colony-forming units (CFU)/100 ml) and E. coli (1-720 CFU/100 ml). Chlorine levels were below 0.2 ppm in seven of the nine samples. Information of 1,815 cases was obtained from the hospital records with a crude attack rate of 2.9%. Cases widespread in the district increased throughout the holiday, epidemic curve revealed a point-source outbreak. The case-control study revealed that consumption of drinking tap water and using it to clean vegetables/fruits were significantly associated with the illness. While drinking only bottled water had a protective effect against the illness. The culture technique showed that the water supply samples were positive for pathogenic bacteria. Upon decision in a multi-stakeholder meeting, the water tank was cleaned, and the Municipality initiated the renovation of the water supply system.
More Related Videos
Related Concept Videos
Drugs Affecting GI Tract Motility: Antimicrobials as Antidiarrheal Agents
Quality of Water
Steps in Outbreak Investigation