Related Experiment Video
Updated: Sep 3, 2025

Author Spotlight: Exploring Self-Assembled MOF-Polymer Composites
Published on: June 14, 2024
Impact of free energy of polymers on polymorphism of polymer-grafted nanoparticles
Masanari Ishiyama1, Kenji Yasuoka1,2, Makoto Asai1,2
1Department of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.
Abstract:
Colloidal crystals have gathered wide attention as a model material for optical applications because of their feasibility in controlling the propagation of light by their crystal structure and lattice spacing as well as the simplicity of their fabrication. However, due to the simple interaction between colloids, the colloidal crystal structures that can be formed are limited. It is also difficult to adjust the lattice spacing. Furthermore, colloidal crystals are fragile compared to other crystals. In this study, we focused on polymer-grafted nanoparticles (PGNP) as a possible solution to these unresolved issues. We expected that PGNPs, composed of two distinct layers (the hard core of a nanoparticle and the soft corona of grafted polymers on the surface), will demonstrate similar behaviors as star polymers and hard spheres. We also predicted that PGNPs may exhibit polymorphism because the interaction between PGNPs strongly depends upon their grafting density and the length of the grafted polymer chains. Moreover, we expected that crystals made from PGNPs will be structurally tough due to the entanglement of grafted polymers. From exploration of crystal polymorphs of PGNPs by molecular dynamics simulations, we found face-centered cubic (FCC)/hexagonal close-packed (HCP) and body-centered cubic (BCC) crystals, depending on the length of the grafted polymer chains. When the chains were short, PGNPs behaved like hard spheres and crystals were arranged in FCC/HCP structure, much like the phase transition observed in an Alder transition. When the chains were long enough, the increase in the free energy of grafted polymers was no longer negligible and crystals were arranged in BCC structure, which has a lower density than FCC/HCP. When the chains were not too short or long, FCC/HCP structures were first observed when the volume fraction of system was small, but a phase transition occurred when the system was further compressed and the crystals arranged themselves in a BCC structure. These results most likely have laid strong foundations for future simulations and experimental studies of PGNP crystals.
Related Concept Videos
Characteristics and Nomenclature of Copolymers
Molecular Weight of Step-Growth Polymers
As the step-growth polymerization involves step-wise condensation of monomers, the molecular weight also builds up eventually. Consequently, high molecular weight polymers are obtained at the late stages of the polymerization, where 99% of monomers have been consumed.
The extent of the...
Polymer Classification: Crystallinity
Crystalline domains are the regions where polymer chains are aligned in an orderly manner and held together in proximity by intermolecular forces. For example, chains in the crystalline domains of polyethylene and nylon are bound together by van der Waals...
Ziegler–Natta Chain-Growth Polymerization: Overview
Step-Growth Polymerization: Overview
Many natural and synthetic polymers are produced by...
Anionic Chain-Growth Polymerization: Overview

