Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Augmentation of MS/MS Libraries with Spectral Interpolation for Improved Identification
Ethan King1, Richard Overstreet2, Julia Nguyen1
1Computing and Analytics Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States.
Abstract:
Tandem mass spectrometry (MS/MS) is a primary tool for the identification of small molecules and metabolites where resultant spectra are most commonly identified by matching them with spectra in MS/MS reference libraries. The high degree of variability in MS/MS spectrum acquisition techniques and parameters creates a significant challenge for building standardized reference libraries. Here we present a method to improve the usefulness of existing MS/MS libraries by augmenting available experimental spectra data sets with statistically interpolated spectra at unreported collision energies. We find that highly accurate spectral approximations can be interpolated from as few as three experimental spectra and that the interpolated spectra will be consistent with true spectra gathered from the same instrument as the experimental spectra. Supplementing existing spectral databases with interpolated spectra yields consistent improvements to identification accuracy on a range of instruments and precursor types. Applying this method yields significant improvements (∼10% more spectra correctly identified) on large data sets (2000-10 000 spectra), indicating this is a quick yet adept tool for improving spectral matching in situations where available reference libraries are not yet sufficient. We also find improvements of matching spectra across instrument types (between an Agilent Q-TOF and an Orbitrap Elite), at high collision energies (50-90 eV), and with smaller data sets available through MassBank.
Related Concept Videos
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometers
High-Resolution Mass Spectrometry (HRMS)