Improving reproducibility and performance of radiomics in low-dose CT using cycle GANs
Junhua Chen1, Leonard Wee1, Andre Dekker1
1Department of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre+, Maastricht, ET, Netherlands.
Background:
As a means to extract biomarkers from medical imaging, radiomics has attracted increased attention from researchers. However, reproducibility and performance of radiomics in low-dose CT scans are still poor, mostly due to noise. Deep learning generative models can be used to denoise these images and in turn improve radiomics' reproducibility and performance. However, most generative models are trained on paired data, which can be difficult or impossible to collect.
Purpose:
In this article, we investigate the possibility of denoising low-dose CTs using cycle generative adversarial networks (GANs) to improve radiomics reproducibility and performance based on unpaired datasets.
Methods And Materials:
Two cycle GANs were trained: (1) from paired data, by simulating low-dose CTs (i.e., introducing noise) from high-dose CTs and (2) from unpaired real low dose CTs. To accelerate convergence, during GAN training, a slice-paired training strategy was introduced. The trained GANs were applied to three scenarios: (1) improving radiomics reproducibility in simulated low-dose CT images and (2) same-day repeat low dose CTs (RIDER dataset), and (3) improving radiomics performance in survival prediction. Cycle GAN results were compared with a conditional GAN (CGAN) and an encoder-decoder network (EDN) trained on simulated paired data.
Results:
The cycle GAN trained on simulated data improved concordance correlation coefficients (CCC) of radiomic features from 0.87 (95%CI, [0.833,0.901]) to 0.93 (95%CI, [0.916,0.949]) on simulated noise CT and from 0.89 (95%CI, [0.881,0.914]) to 0.92 (95%CI, [0.908,0.937]) on the RIDER dataset, as well improving the area under the receiver operating characteristic curve (AUC) of survival prediction from 0.52 (95%CI, [0.511,0.538]) to 0.59 (95%CI, [0.578,0.602]). The cycle GAN trained on real data increased the CCCs of features in RIDER to 0.95 (95%CI, [0.933,0.961]) and the AUC of survival prediction to 0.58 (95%CI, [0.576,0.596]).
Conclusion:
The results show that cycle GANs trained on both simulated and real data can improve radiomics' reproducibility and performance in low-dose CT and achieve similar results compared to CGANs and EDNs.
More Related Videos
10:17Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...