Related Experiment Video
Updated: Sep 3, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Fourier-based decomposition for simultaneous 2-voxel MRS acquisition with 2SPECIAL
Layla Tabea Riemann1, Christoph Stefan Aigner1, Ralf Mekle2
1Physikalisch-Technische Bundesanstalt (PTB), Braunschweig und Berlin, Germany.
This study introduces a faster method for brain spectroscopy using the 2SPECIAL sequence and voxel-GRAPPA. This technique simultaneously acquires signals from two voxels, reducing scan time by 21.6% without losing spectral quality.
Area of Science:
- Magnetic Resonance Imaging
- Spectroscopy
- Neuroimaging
Background:
- Simultaneous multi-voxel spectroscopy (sMVS) is crucial for efficient brain imaging.
- Existing methods can be time-consuming, limiting clinical applications.
- Advanced pulse sequences and decomposition algorithms are needed to improve efficiency.
Purpose of the Study:
- To develop and validate a simultaneous multi-voxel spectroscopy (sMVS) technique at 7 Tesla using a novel multi-banded sequence.
- To introduce and assess a voxel-GRAPPA (vGRAPPA) decomposition method for accurate signal separation.
- To evaluate the performance and limitations of the proposed 2SPECIAL sequence and vGRAPPA algorithm.
Main Methods:
- Implementation of a 2 spin-echo, full-intensity acquired localized (2SPECIAL) sequence with a wideband, uniform rate, smooth truncation (WURST) multi-banded pulse.
- Development of a voxel-GRAPPA (vGRAPPA) algorithm for signal decomposition and comparison with SENSE-based methods.
- Evaluation of two-voxel excitation, adiabatic inversion pulses, and B0/B1 adjustments for in vivo brain applications.
Main Results:
- The 2SPECIAL sequence enabled sMVS with a 21.6% reduction in scan time compared to consecutive acquisitions, maintaining signal-to-noise ratio (SNR).
- The vGRAPPA algorithm accurately reassigned spectral signals to their origin voxels, showing comparable performance to SENSE regarding leakage (<10%) and Cramér-Rao lower bounds (CRLB).
- vGRAPPA reduced motion sensitivity by eliminating the need for additional sensitivity map acquisitions.
Conclusions:
- The 2SPECIAL sequence combined with vGRAPPA offers a significant reduction in measurement time for multi-voxel spectroscopy.
- This approach maintains spectral quality and metabolite quantification accuracy.
- It presents a valuable new option for advanced multi-voxel applications in neuroimaging.
Related Concept Videos
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
2D NMR: Overview of Heteronuclear Correlation Techniques
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

