Noninvasive blood pressure measurement in patients with continuous-flow left ventricular assist devices
Aiko Tanaka1, Yuki Kiriyama2, Naoko Kubo3
1Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, 2-15 Yamadaoka, Suita, Osaka, 565-0871, Japan. aikotanakaicu@gmail.com.
Abstract:
Oscillatory blood pressure (OBP) with a slow cuff-deflation system has been proposed as noninvasive measurement of mean arterial pressure (MAP) in patients with continuous-flow left ventricular assist devices (LVADs). However, the challenge is that the measurement is not obtainable in certain patients. We hypothesized that the combined use of color Doppler imaging during OBP measurement (CDBP) could derive MAP accurately. We conducted a prospective observational study in critically ill patients (30 patients with continuous-flow LVADs and 30 control patients without LVADs). Triplicate OBP and CDBP measurements were performed and invasive blood pressure (IBP) was recorded. The overall success rate of OBP was 63.3% in the LVAD group and 98.9% in the control group. The CDBP was successfully obtained in 100% of all study patients. The CDBP in the LVAD group was closest to the MAP of measured IBP, while that in the control group was closest to the systolic IBP. The mean absolute differences in OBP and CDBP from the closest IBP were similar in both the control and LVAD groups. In nonpulsatile LVAD patients with a pulse pressure IBP < 10 mmHg, the success rate of OBP measurement was only 10.0%, and CDBP showed significantly reduced error in MAP measurement (mean absolute difference: OBP 23.2 ± 8.7 vs CDBP 5.2 ± 3.6 mmHg, p < 0.001). The validity of OBP measurement with a slow cuff-deflation system limited particularly in nonpulsatile LVAD patients. The concurrent use of color Doppler imaging is encouraged for more accurate measurement of MAP in patients with continuous-flow LVADs.
More Related Videos
06:29Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
09:37Permanent Ligation of the Left Anterior Descending Coronary Artery in Mice: A Model of Post-myocardial Infarction Remodelling and Heart Failure
Published on: December 2, 2014
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.