Related Experiment Video
Updated: Sep 3, 2025

Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Localization-adjusted diagnostic performance and assistance effect of a computer-aided detection system for
Sun Yeop Lee1, Sangwoo Ha1, Min Gyeong Jeon1
1Department of Medical Artificial Intelligence, Deepnoid, Inc., Seoul, Republic of Korea.
Abstract:
While many deep-learning-based computer-aided detection systems (CAD) have been developed and commercialized for abnormality detection in chest radiographs (CXR), their ability to localize a target abnormality is rarely reported. Localization accuracy is important in terms of model interpretability, which is crucial in clinical settings. Moreover, diagnostic performances are likely to vary depending on thresholds which define an accurate localization. In a multi-center, stand-alone clinical trial using temporal and external validation datasets of 1,050 CXRs, we evaluated localization accuracy, localization-adjusted discrimination, and calibration of a commercially available deep-learning-based CAD for detecting consolidation and pneumothorax. The CAD achieved image-level AUROC (95% CI) of 0.960 (0.945, 0.975), sensitivity of 0.933 (0.899, 0.959), specificity of 0.948 (0.930, 0.963), dice of 0.691 (0.664, 0.718), moderate calibration for consolidation, and image-level AUROC of 0.978 (0.965, 0.991), sensitivity of 0.956 (0.923, 0.978), specificity of 0.996 (0.989, 0.999), dice of 0.798 (0.770, 0.826), moderate calibration for pneumothorax. Diagnostic performances varied substantially when localization accuracy was accounted for but remained high at the minimum threshold of clinical relevance. In a separate trial for diagnostic impact using 461 CXRs, the causal effect of the CAD assistance on clinicians' diagnostic performances was estimated. After adjusting for age, sex, dataset, and abnormality type, the CAD improved clinicians' diagnostic performances on average (OR [95% CI] = 1.73 [1.30, 2.32]; p < 0.001), although the effects varied substantially by clinical backgrounds. The CAD was found to have high stand-alone diagnostic performances and may beneficially impact clinicians' diagnostic performances when used in clinical settings.
Related Concept Videos
Pneumonia III: Complications and Assessment
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Pneumothorax-II
Clinical Manifestations:
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...

