Related Experiment Video
Updated: Sep 2, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
A novel stochastic optimization method for handling misalignments of proton and photon doses in combined treatments
Silvia Fabiano1, Nathan Torelli1, Dávid Papp2
1Department of Radiation Oncology, University Hospital Zürich, Zürich, Switzerland.
Abstract:
Objective.Combined proton-photon treatments, where most fractions are delivered with photons and only a few are delivered with protons, may represent a practical approach to optimally use limited proton resources. It has been shown that, when organs at risk (OARs) are located within or near the tumor, the optimal multi-modality treatment uses protons to hypofractionate parts of the target volume and photons to achieve near-uniform fractionation in dose-limiting healthy tissues, thus exploiting the fractionation effect. These plans may be sensitive to range and setup errors, especially misalignments between proton and photon doses. Thus, we developed a novel stochastic optimization method to directly incorporate these uncertainties into the biologically effective dose (BED)-based simultaneous optimization of proton and photon plans.Approach.The method considers the expected valueEband standard deviationσbof the cumulative BEDbin every voxel of a structure. For the target, a piecewise quadratic penalty function of the formbmin-Eb-2σb+2is minimized, aiming for plans in which the expected BED minus two times the standard deviation exceeds the prescribed BEDbmin.Analogously,Eb+2σb-bmax+2is considered for OARs.Main results.Using a spinal metastasis case and a liver cancer patient, it is demonstrated that the novel stochastic optimization method yields robust combined treatment plans. Tumor coverage and a good sparing of the main OARs are maintained despite range and setup errors, and especially misalignments between proton and photon doses. This is achieved without explicitly considering all combinations of proton and photon error scenarios.Significance.Concerns about range and setup errors for safe clinical implementation of optimized proton-photon radiotherapy can be addressed through an appropriate stochastic planning method.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by