Related Experiment Video
Updated: Dec 14, 2025

Author Spotlight: Advancing Rapid Detection of Respiratory Pathogens Using Microfluidic Chip
Published on: March 29, 2024
Wearable CNTs-based humidity sensors with high sensitivity and flexibility for real-time multiple respiratory
Han-Sem Kim1, Ji-Hye Kang2,3, Ji-Young Hwang4
1Institute of Tissue Regeneration Engineering (ITREN), Dankook University, Cheonan, 31116, South Korea. massem@dankook.ac.kr.
Abstract:
Sensors, such as optical, chemical, and electrical sensors, play an important role in our lives. While these sensors already have widespread applications, such as humidity sensors, most are generally incompatible with flexible/inactive substrates and rely on conventional hard materials and complex manufacturing processes. To overcome this, we develop a CNT-based, low-resistance, and flexible humidity sensor. The core-shell structured CNT@CPM is prepared with Chit and PAMAM to achieve reliability, accuracy, consistency, and durability, resulting in a highly sensitive humidity sensor. The average response/recovery time of optimized sensor is only less than 20 s, with high sensitivity, consistent responsiveness, good linearity according to humidity rates, and low hysteresis (- 0.29 to 0.30 %RH). Moreover, it is highly reliable for long-term (at least 1 month), repeated bending (over 15,000 times), and provides accurate humidity measurement results. We apply the sensor to smart-wear, such as masks, that could conduct multi-respiratory monitoring in real-time through automatic ventilation systems. Several multi-respiratory monitoring results demonstrate its high responsiveness (less than 1.2 s) and consistent performance, indicating highly desirable for healthcare monitoring. Finally, these automatic ventilation systems paired with flexible sensors and applied to smart-wear can not only provide comfort but also enable stable and accurate healthcare in all environments.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...

