Related Experiment Video
Updated: Sep 2, 2025

Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Characterization of compliance phenotypes in COVID-19 acute respiratory distress syndrome
Lucia Zacchetti1, Luca Longhi2, Isabella Bianchi2
1Department of Anesthesia, Emergency and Critical Care Medicine, Papa Giovanni XXIII Hospital, Piazza OMS 1, 24127, Bergamo, Italy. lzacchetti@asst-pg23.it.
Background:
Coronavirus disease 2019-associated acute respiratory distress syndrome (COVID-19 ARDS) seems to differ from the "classic ARDS", showing initial significant hypoxemia in the face of relatively preserved compliance and evolving later in a scenario of poorly compliant lungs. We tested the hypothesis that in patients with COVID-19 ARDS, the initial value of static compliance of respiratory system (Crs) (1) depends on the previous duration of the disease (i.e., the fewer days of illness, the higher the Crs and vice versa) and (2) identifies different lung patterns of time evolution and response to prone positioning.
Methods:
This was a single-center prospective observational study. We enrolled consecutive mechanically ventilated patients with a diagnosis of COVID-19 who met ARDS criteria, admitted to intensive care unit (ICU). Patients were divided in four groups based on quartiles of initial Crs. Relationship between Crs and the previous duration of the disease was evaluated. Respiratory parameters collected once a day and during prone positioning were compared between groups.
Results:
We evaluated 110 mechanically ventilated patients with a diagnosis of COVID-19 who met ARDS criteria admitted to our ICUs. Patients were divided in groups based on quartiles of initial Crs. The median initial Crs was 41 (32-47) ml/cmH2O. No association was found between the previous duration of the disease and the initial Crs. The Crs did not change significantly over time within each quartile. Positive end-expiratory pressure (PEEP) and driving pressure were respectively lower and greater in patients with lower Crs. Prone positioning significantly improved PaO2/FiO2 in the 4 groups, however it increased the Crs significantly only in patients in lower quartile of Crs.
Conclusions:
In our cohort, the initial Crs is not dependent on the previous duration of COVID-19 disease. Prone positioning improves oxygenation irrespective to initial Crs, but it ameliorates respiratory mechanics only in patients with lower Crs.
Related Concept Videos
Acute Respiratory Failure-IV
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-III