Spectral Encoder to Extract the Features of Near-Infrared Spectra for Multivariate Calibration
Chaoshu Duan1,2, Xuyang Liu1,2, Wensheng Cai1,2
1Research Center for Analytical Sciences, Frontiers Science Center for New Organic Matter, College of Chemistry, Tianjin Key Laboratory of Biosensing and Molecular Recognition, State Key Laboratory of Medicinal Chemical Biology, Nankai University, Tianjin 300071, China.
Abstract:
An autoencoder architecture was adopted for near-infrared (NIR) spectral analysis by extracting the common features in the spectra. Three autoencoder-based networks with different purposes were constructed. First, a spectral encoder was established by training the network with a set of spectra as the input. The features of the spectra can be encoded by the nodes in the bottleneck layer, which in turn can be used to build a sparse and robust model. Second, taking the spectra of one instrument as the input and that of another instrument as the reference output, the common features in both spectra can be obtained in the bottleneck layer. Therefore, in the prediction step, the spectral features of the second can be predicted by taking the reverse of the decoder as the encoder. Furthermore, transfer learning was used to build the model for the spectra of more instruments by fine-tuning the trained network. NIR datasets of plant, wheat, and pharmaceutical tablets measured on multiple instruments were used to test the method. The multi-linear regression (MLR) model with the encoded features was found to have a similar or slightly better performance in prediction compared with the partial least-squares (PLS) model.
More Related Videos
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrometers
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview