A red-emitting Europium(III) complex as a luminescent probe with large Stokes shift for the sequential determination
Jie Zhang1, Xibin Zhou2, Jun Wang3
1College of Chemistry, Liaoning University, Shenyang 110036, PR China; College of Pharmacy, Jinzhou Medical University, 121001, PR China.
Abstract:
In this work, a novel Eu3+-DTPA-bis(AMC) complex with red luminescence was designed and synthesized for sequential detection of Cu2+ and biothiols (Cys/Hcy/GSH) based on the displacement strategy with the good selectivity, high sensitivity, and large Stokes shift (288 nm). The possible detection mechanism was verified by UV-vis, the high-resolution mass spectrometry, and the fluorescence decay curve. The experimental parameters, including the solution pH, the incubation time, the concentration ratio of Eu3+-DTPA-bis(AMC) to Cu2+ and biothiols concentration, were optimized. Under the optimal conditions, it shows a good linear relationship between the concentration (0-10 μM) of Cu2+ and the fluorescence intensity of Eu3+-DTPA-bis(AMC), with a low detection limit of 0.065 μM. The linear range and the limit of detection of the Eu3+-DTPA-bis(AMC)/Cu2+ system for Cys/Hcy/GSH were 2.5-22.5/5-45/5-50 μM and 0.11/0.07/0.05 μM, respectively. Surprisingly, the high or low concentration of Eu3+-DTPA-bis(AMC)/Cu2+ can significantly affect the selectivity of the sensing system to biothiols (Cys/GSH/Hcy). When the concentration of the Eu3+-DTPA-bis(AMC)/Cu2+ system is 10.0 μΜ, it could recognize biothiols (Cys/GSH/Hcy) from other substances, but when the concentration is as low as 3.3 μM, it could further specifically distinguished Cys from Hcy/GSH. Owing to the high anti-interference characteristics, accuracy and specificity, the sensing system was well applied to the cascade detection of Cu2+ in actual environmental samples and Cys in biological and food samples, including FBS, urine, milk, beverage, fresh juice with the satisfactory recoveries from 96.20 to 106.80 %.
More Related Videos
13:21Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
12:52IridiumIII Luminescent Probe for Detection of the Malarial Protein Biomarker Histidine Rich Protein-II
Published on: July 7, 2015
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Photoluminescence: Applications
Complexometric Titration: Overview
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...