Patient's posteroanterior chest radiographs are routinely displayed at different sizes on PACS: Cause and prevalence
A D Stirling1, M C Murphy1, W L Murray2
1Department of Radiology, Mater Misericordiae University Hospital, Dublin 7, Ireland; School of Medicine, University College Dublin, Ireland.
Objective:
Sequential posteroanterior chest radiographs (CXRs) on any one patient are commonly displayed at different sizes on PACS monitors. The purpose of this study was to determine the cause of these differences, the percentage of radiographs affected, the relative change in magnification seen and if radiologists were aware of this display difference.
Methods:
Differences in routine radiographer collimation pre-acquisition and image cropping (shuttering) post acquisition were noted. From three different hospitals, 300 posteroanterior (PA) erect CXRs with prior comparative studies were viewed side-by-side on a standard landscape display monitor. Variation in display size was calculated using the number of detector elements in the autofitted axis of the radiograph, when compared with the prior study. Correlation between patient gender and extent of magnification between images was recorded. Following this, a national survey was circulated to see if radiologists were aware of this phenomenon.
Results:
Large variations in display size were noted. The mean extent of magnification between sequential PA chest radiographs was ±6.8% (range 0-21.6%). 98% of CXRs had some degree of variability in display size. There was no significant difference in the extent of variation in magnification based on age or gender. 86% of the radiologists who responded to the survey (n = 132) were unaware of any display size variability.
Conclusion:
Sequential DR acquired chest radiographs are routinely displayed with varying degrees of magnification on PACS monitors due to differences in radiographer practice and auto-fit display settings. Most radiologists surveyed were unaware of these differences and their causation.
More Related Videos
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
04:57Prone Lateral Minimally Invasive Retropleural Corpectomy Using a Rotatable Radiolucent Jackson Table
Published on: July 3, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Pneumothorax-II
Clinical Manifestations:
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Radiological Investigation I: X-ray and CT