Related Experiment Video
Updated: Sep 2, 2025

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Technical note: a nose ring sensor system to monitor dairy cow cardiovascular and respiratory metrics
Yael Salzer1, Guy Lidor1, Lavie Rosenfeld1
1Institute of Agricultural Engineering, Agricultural Research Organization-Volcani Institute, Rishon LeZion 7505101, Israel.
Abstract:
Monitoring cardiovascular and respiratory measurements corresponds to the precision livestock farming (PLF) objective to continuously monitor and assess dairy cows' welfare and health. Changes in heart rate, breathing rate, and oxygen saturation (SpO2) are valuable metrics in human and veterinary medicine to assess stress, pain, illness, and detect critical conditions. The common way to measure heart rate is either manually or with a stethoscope. Under research conditions, heart rate is usually measured with a sports watch chest belt. Breathing rate is obtained by counting the cow's flank movements which is a time-consuming and labor-intensive method that requires training and is prone to human error. No devices are available on the market that enable practical and easy pulse oximetry in farm animals. This study presents a wireless nose ring sensor system (NoRS) composed of thermal and photoplothysmography sensors that attach to the nostrils of four Holstein dairy cows. The NoRS's thermocouple measured the cow's nasal cavity air temperature; an optic sensor measured the IR (660 nm) and RED (660 nm) signals reflected from the cow's nasal septum. Breathing was calculated from the thermocouple signal's center frequency with a fast Fourier transformation or the signal peak count (i.e., oscillations). The breathing rate was compared to breathing observed by concurrently counting the flank movements. Heart rate and SpO2 were measured by integrated pulse oximetry and heart rate monitor module (MAX30101 TinyCircuit) assembled on the NoRS circuit. Heart rate was also measured with FFT and by counting the number of peaks from the optic sensor's raw IR and RED signals. These measures were compared to an off-the-shelf hand-held pulse oximeter's heart rate and SpO2 readings during the same time. The comparisons revealed highly significant correlations for the heart rate readings where the strength of the correlation was sensitive to the method. The correlation between breathing rate and the veterinarian's visual observations was low, albeit significant. Thus, inhale-exhale cycle counting constitutes a more precise approach than flank movement counts. The hand-held device's 96% SpO2 is compatible with near-saturation values expected in healthy cows. The mean NoRS SpO2 reading was 3% less. After further piloting under field conditions, the NoRS will require no animal restraining to automatically and continuously record cows' breathing rate, heart rate, and SpO2.
More Related Videos
10:25Multi-system Monitoring for Identification of Seizures, Arrhythmias and Apnea in Conscious Restrained Rabbits
Published on: March 27, 2021
11:02The Use of an Automated System GreenFeed to Monitor Enteric Methane and Carbon Dioxide Emissions from Ruminant Animals
Published on: September 7, 2015
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: