Design, construction, and operation of a 2 T 240 mm conduction-cooled defect-irrelevant winding (RE) Ba2Cu3O7-x

Uijong Bong1, Kibum Choi1, Jaemin Kim1

  • 1Department of Electrical and Computer Engineering, Seoul National University, Gwanak-ro 1, Gwanak-gu, Seoul 08826, South Korea.

Related Concept Videos

Toroids01:27

Toroids

A toroid is a closely wound donut-shaped coil constructed using a single  conducting wire. In general, it is assumed that a toriod consists of  multiple circular loops perpendicular to its axis.
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb...
3.1K
Magnetic Field Due to Two Straight Wires01:18

Magnetic Field Due to Two Straight Wires

Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
2.8K
Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
675
Eddy Currents01:25

Eddy Currents

Since eddy currents occur only in conductors, magnets can separate metals from other materials. For example, in a recycling center, trash is dumped in batches down a ramp, beneath which lies a powerful magnet. Conductors in the trash are slowed by eddy currents, while nonmetals in the trash move on, separating from the metals. This works for all metals, not just ferromagnetic ones.
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
1.7K
Three-Winding Transformers01:19

Three-Winding Transformers

Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
296
Torque On A Current Loop In A Magnetic Field01:13

Torque On A Current Loop In A Magnetic Field

The most common application of magnetic force on current-carrying wires is in electric motors. These consist of loops of wire, which are placed between the magnets with a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate, thus converting electrical energy to mechanical energy.
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
4.6K