Related Experiment Video
Updated: Sep 2, 2025

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Performance and usability testing of an automated tool for detection of peripheral artery disease using electronic
I Ghanzouri1, S Amal1, V Ho1
1Division of Vascular Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA, USA.
Abstract:
Peripheral artery disease (PAD) is a common cardiovascular disorder that is frequently underdiagnosed, which can lead to poorer outcomes due to lower rates of medical optimization. We aimed to develop an automated tool to identify undiagnosed PAD and evaluate physician acceptance of a dashboard representation of risk assessment. Data were derived from electronic health records (EHR). We developed and compared traditional risk score models to novel machine learning models. For usability testing, primary and specialty care physicians were recruited and interviewed until thematic saturation. Data from 3168 patients with PAD and 16,863 controls were utilized. Results showed a deep learning model that utilized time engineered features outperformed random forest and traditional logistic regression models (average AUCs 0.96, 0.91 and 0.81, respectively), P < 0.0001. Of interviewed physicians, 75% were receptive to an EHR-based automated PAD model. Feedback emphasized workflow optimization, including integrating risk assessments directly into the EHR, using dashboard designs that minimize clicks, and providing risk assessments for clinically complex patients. In conclusion, we demonstrate that EHR-based machine learning models can accurately detect risk of PAD and that physicians are receptive to automated risk detection for PAD. Future research aims to prospectively validate model performance and impact on patient outcomes.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease I: Introduction
Peripheral Artery Disease III: Interprofessional Care
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: