Related Experiment Video
Updated: Sep 2, 2025

The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
Management of MRI-Detected Benign Internal Mammary Lymph Nodes
Gozde Gunes1, Priscila Crivellaro2, Derek Muradali2
1Department of Radiology, Baskent University Hospital, Çankaya/Ankara, Turkey.
Abstract:
Introduction In this retrospective study, we aimed to evaluate benign internal mammary lymph nodes (IMLNs) in terms of frequency, number, size, long axis/short axis (L/S) ratio, intercostal location, presence of fatty hilum, and stability using breast magnetic resonance imaging (MRI) and discuss the findings by reviewing existing literature. Methods This single-center study consisted of 130 women between the ages of 24 and 76 years, who had at least two breast MRI examinations in our institution, with the latest exam performed between January 1, 2019 and November 1, 2019, were eligible for the study. MRIs of the study group were independently reviewed by two radiologists. Results IMLN was detected in 31.1% of the 427 MRIs, with a total number of 256 nodes. The most common indication for breast MRI was high-risk screening (66.2%). The median number of nodes per patient was 1 (range: 1-6). The median follow-up time was 19.5 months (range: 6-141 months). None of these benign nodes showed significant interval growth. Mean L/R ratio of the nodes was 1.9. One hundred and four nodes ( n = 104, 40.6%) had a L/S ratio less than 2 and 43.2% ( n = 45) of the nodes with a L/S ratio less than 2, had a long axis measuring less than or equal to 3mm. IMLN of patients with breast implants had the largest mean long axis. The fatty hilum was identified in 34.3% ( n = 68) of the 256 nodes. The size of the lymph nodes where fatty hilum was visualized was significantly larger than the ones where fatty hilum was not visualized ( p < 0.001). Fatty hilum could be visualized in only 2.7% of the nodes with a long axis smaller than 3 mm. Conclusion IMLN is a frequent finding on breast MRI. We have shown that benign IMLNs might be large sized in specific cases like patients with breast implants. When small sized (≤3mm), they are more likely to be rounded (L/S ratio <2). The fatty hilum that is a feature of benignity might not be visualized in nodes less than or equal to3mm.
More Related Videos
13:35Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
07:30Electromagnetic Navigation Transthoracic Nodule Localization for Minimally Invasive Thoracic Surgery
Published on: May 4, 2022