Accuracy of virtual non-contrast images with different algorithms in dual-energy computed tomography
Yumi Takane1, Kazuhiro Sato2, Ryota Kageyama2
1Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan. yumi-takane@med.tohoku.ac.jp.
Abstract:
We investigated the accuracy of the computed tomography (CT) numbers of virtual non-contrast (VNC) images for two different material decomposition algorithms using the same image data for different diluted contrast agent concentrations. A container filled with contrast agents was inserted into a cylindrical phantom and scanned with dual-energy protocols (80/Sn140 kV, 100/Sn140 kV) using a dual-source CT. VNC images were generated by the 2-material decomposition (MD) algorithm using the energy of each tube voltage and the linear attenuation coefficient, calculated from the theoretical spectral curve of the agent and the CT number of the image, respectively. Furthermore, VNC images using 3-material decomposition (3-MD) algorithm were produced by applying LiverVNC, an analysis parameter implemented in the scanner. The robustness of both the algorithms was verified by investigating the CT numbers of the agents in the VNC. The closer the CT number is to 0 HU, the more robust the algorithm. Without beam-hardening correction, the CT numbers increased with an increase in concentration in both the algorithms, maximal at 50 mg/ml concentration, with CT numbers of 38 HU for 2-MD, 86 HU for 3-MD. With correction, CT numbers were ± 10 HU or less for both the algorithms up to 30 mg/ml concentration, whereas, for concentrations above 40 mg/ml, the maximal averaged CT number was 12 HU for 2-MD, 22 HU for 3-MD. For both the algorithms, the accuracy of the CT numbers was maintained in the low-concentration range; parameter adjustment was necessary to maintain the accuracy at concentrations higher than clinically expected.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT