Related Experiment Video
Updated: Sep 2, 2025
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)
Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment
Published on: April 25, 2025
89Zr-panitumumab Combined With 18F-FDG PET Improves Detection and Staging of Head and Neck Squamous Cell Carcinoma
Yu-Jin Lee1, Nynke S van den Berg2, Heying Duan3
1Department of Otolaryngology-Head and Neck Surgery, Stanford University School of Medicine. Stanford, California.
Purpose:
Determine the safety and specificity of a tumor-targeted radiotracer (89Zr-pan) in combination with 18F-FDG PET/CT to improve diagnostic accuracy in head and neck squamous cell carcinoma (HNSCC).
Experimental Design:
Adult patients with biopsy-proven HNSCC scheduled for standard-of-care surgery were enrolled in a clinical trial and underwent systemic administration of 89Zirconium-panitumumab and panitumumab-IRDye800 followed by preoperative 89Zr-pan PET/CT and intraoperative fluorescence imaging. The sensitivity, specificity, and AUC were evaluated.
Results:
A total of fourteen patients were enrolled and completed the study. Four patients (28.5%) had areas of high 18F-FDG uptake outside the head and neck region with maximum standardized uptake values (SUVmax) greater than 2.0 that were not detected on 89Zr-pan PET/CT. These four patients with incidental findings underwent further workup and had no evidence of cancer on biopsy or clinical follow-up. Forty-eight lesions (primary tumor, LNs, incidental findings) with SUVmax ranging 2.0-23.6 were visualized on 18F-FDG PET/CT; 34 lesions on 89Zr-pan PET/CT with SUVmax ranging 0.9-10.5. The combined ability of 18F-FDG PET/CT and 89Zr-pan PET/CT to detect HNSCC in the whole body was improved with higher specificity of 96.3% [confidence interval (CI), 89.2%-100%] compared to 18F-FDG PET/CT alone with specificity of 74.1% (CI, 74.1%-90.6%). One possibly related grade 1 adverse event of prolonged QTc (460 ms) was reported but resolved in follow-up.
Conclusions:
89Zr-pan PET/CT imaging is safe and may be valuable in discriminating incidental findings identified on 18F-FDG PET/CT from true positive lesions and in localizing metastatic LNs.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

