Related Experiment Video
Updated: Sep 2, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Physical Activity in Cardiac Implantable Electronic Device Recipients During the COVID-19 Pandemic
Abhishek J Deshmukh1, Camden Harrell2, Jacob Hicks2
1Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA.
Insights
Physical activity (PA) significantly decreased in patients with cardiac implantable electronic devices (CIEDs) during the COVID-19 pandemic. This reduction in PA was observed across all demographics and device types in 2020 compared to 2019.
Area of Science:
- Cardiology
- Public Health
- Biomedical Engineering
Background:
- The COVID-19 pandemic has impacted lifestyle behaviors globally.
- Understanding the effects on patients with cardiac implantable electronic devices (CIEDs) is crucial for cardiovascular health.
- Physical activity (PA) is a key determinant of cardiovascular outcomes.
Purpose of the Study:
- To quantify the changes in physical activity (PA) levels among patients with CIEDs during the COVID-19 pandemic.
- To compare PA levels in 2020 with the pre-pandemic period of 2019.
Main Methods:
- Retrospective analysis of PA data from the BIOTRONIK CERTITUDE Registry.
- Comparison of mean daily and weekly PA from January to August 2020 versus the same period in 2019.
- Inclusion of 21,660 patients with CIEDs.
Main Results:
- A significant decline in daily PA was observed after the pandemic declaration in 2020.
- The maximum mean reduction in PA was -24.5±36.3 minutes in April 2020 compared to 2019 (P<.0001).
- PA remained lower throughout 2020 compared to 2019 across all patient subgroups.
Conclusions:
- The COVID-19 pandemic led to a substantial decrease in daily physical activity for individuals with CIEDs.
- Further research is needed to assess the long-term cardiovascular implications of this PA reduction.
Objective:
To characterize the physical activity (PA) level in patients with a cardiac implantable electronic device (CIED) during the coronavirus disease 2019 (COVID-19) pandemic and compare PA level during the pandemic in 2020 with the year 2019.
Methods:
We performed a retrospective analysis of PA activity in individuals implanted with a CIED enrolled in the BIOTRONIK CERTITUDE Registry. Mean daily and weekly PA from January to August 2020 was compared with 2019.
Results:
A total of 21,660 individuals met eligibility criteria, with mean age of 72.6±11.6 years, and 12,411 (57.3)% were males. A significant decline in daily PA was noted following the pandemic declaration in 2020, with a maximum mean reduction of -24.5±36.3 minutes (P<.0001) observed in April 2020 compared with 2019. PA in 2020 increased from April to May (120.6±67.4 to 129.2±70.9 min/d). PA was lower for all months in 2020 compared with 2019. The decrease in PA was observed in all prespecified groups based on age, sex, type of device, and region of the country.
Conclusion:
After the declaration of the coronavirus disease 2019 pandemic, a significant decline in daily PA was observed in individuals with a CIED. Future investigation to establish the impact of this reduction on short and long-term cardiovascular outcomes is required.
Related Concept Videos
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Cardiopulmonary Resuscitation III: AED Use