Evaluation of sample preparation methods for suspect and non-target screening in water, sediment, and biota samples using gas chromatography coupled to high-resolution mass spectrometry
Related Experiment Video
Updated: Sep 2, 2025

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Wonjin Sim1, Sol Choi2, Heon-Jun Lee2
1Institute for Environment and Energy, Pusan National University, Busan 46241, Republic of Korea.
Abstract:
In this study, the sample preparation methods were proposed for the suspect and non-target screening (SNTS) using gas chromatography coupled to high-resolution mass spectrometry in the aquatic environment. The pretreatment methods were evaluated based on detection rates, recoveries, and screening detection limits (SDLs) for 316 substances spiked into surface water, sediment, and biota samples. The detection rates of the spiked compounds were 92.1 % and 98.7 % by the sample preparation methods for water (solid-phase extraction using HLB cartridge) and sediment (ultrasonic extraction (USE) with HLB cartridge clean-up), respectively. Similarly, USE with HLB cartridge clean-up gave the highest detection rate (87.9 %) for biota samples; however, additional pretreatment method using deactivated silica gel clean-up was necessary for the detection of persistent organic pollutants (POPs). The SDL ranges of spiked compounds by the suggested pretreatment methods were 0.01-23.5 ng/L for surface water, 0.02-37.5 ng/g dry weight for sediment, and 0.01-12.2 ng/g wet weight for biota. Although some pollutants, such as POPs had SDLs that were higher than the levels normally detected in the aquatic environment as reported in previous studies, the analytical methods suggested in the present study were satisfactory for the SNTS of most pollutants originated from anthropogenic sources.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...

