Related Experiment Video
Updated: Sep 2, 2025

Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
Detection of hepatitis E virus genotype 3 in wastewater by an electrochemical genosensor
Daniel Alzate1, Maria C Lopez-Osorio2, Fabián Cortés-Mancera3
1Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67, N.° 52-20, Medellín, 050010, Colombia.
Abstract:
Hepatitis E Virus (HEV) is an etiologic agent of hepatitis worldwide. HEV genotype 3 is the most prevalent in non-endemic regions, identified in humans, pigs and environmental samples. Thus, considering the zoonotic nature of HEV genotype 3, viral genome detection in wastewater concerns public health authorities. Electrochemical biosensors are promising analytical tools for viral genome detection in outside settings. This work reports on a highly specific, sensitive and portable electrochemical genosensor to detect HEV genotype 3 in wastewater samples. Based on the alignment analysis of HEV genotype 3 genome sequences available in GenBank, highly specific DNA target probes were designed to hybridize a target sequence within the ORF2/ORF3 overlapping genome region of HEV in between a biotinylated capture probe and a signal probe labeled with digoxigenin, in a sandwich-type format. An anti-Dig antibody labeled with the horseradish peroxidase (HRP) enzyme allowed electrochemical detection. The specificity of the target molecular probes of the viral genome was determined before the biosensor assembly by in silico analysis, PCR and qPCR assays demonstrating efficient amplification of two targets, i.e., nucleotides 5338-5373 and 5328-5373, but this last one of higher performance. The electrochemical response of the genosensor with synthetic HEV was target concentration-dependent in a linear range from 300 pM to 2.4 nM, with a sensitivity of 16.93 μA/nM, a LOD 1.2 pM and high reproducibility. The genosensor response was differential when interrogated with the HEV genotype 3 viral genomes from wastewater against other four viruses. Therefore, the approach offers a step forward to the epidemiologic surveillance of viruses in wastewater as an early warning system.
More Related Videos
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
13:32VirWaTest, A Point-of-Use Method for the Detection of Viruses in Water Samples
Published on: May 11, 2019