Related Experiment Video
Updated: Sep 2, 2025

An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Interference of preservatives on urinary iodine measurement by Sandell-Kolthoff method
Elif Kaya1, Murat Usta2, Ömer Emecen2
1Master of Science Degree Program in Medical Biochemistry, Institute of Health Sciences, Giresun University, Giresun, Turkey.
Abstract:
This report aimed to determine the effects of different preservatives used to maintain the integrity of urine samples for a 24-hour urine collection on urinary iodine measurement by the Sandell-Kolthoff method in vitro. The selected preservatives were hydrochloric acid, acetic acid, boric acid, sodium carbonate, sodium fluoride, thymol with isopropanol, sodium chloride with formalin, and Saccomanno fixative. The test samples to which these preservatives were added and the control samples for basal measurements were prepared from the urine pool obtained from urine samples taken from healthy volunteers. The urinary iodine measurements were performed following the calculated minimum number of replicates in these prepared samples. The data analysis of the interferences of the preservatives was performed based on the Clinical and Laboratory Standards Institute EP7-A2 guideline. The preservatives that had more acceptable effects on the urinary iodine measurement compared to the others were sodium carbonate (0.5% w/v) and thymol (10% w/v) with isopropanol (0.25% v/v) for 24-hour storage at room temperature. This report presented reliable and usable data revealing the effects of preservatives, which are frequently used to maintain the integrity of urine samples for a 24-hour urine collection, on urinary iodine measurement. There are need to reveal the possible effects of potential exogenous interfering substances and the pathological levels of endogenous analytes or shaped elements in the urine matrix on methods with routine clinical use in making medical decisions.
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Urine Studies II: Urine Culture and Sensitivity Test
Precipitation Titration Curve: Analysis

