Related Experiment Video
Updated: Sep 2, 2025

Presynaptic Dopamine Dynamics in Striatal Brain Slices with Fast-scan Cyclic Voltammetry
Published on: January 12, 2012
Second-Derivative-Based Background Drift Removal for a Tonic Dopamine Measurement in Fast-Scan Cyclic Voltammetry
Seongtak Kang1, Jeongrak Park2, Yunho Jeong3
1Department of Electrical Engineering and Computer Science, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333, Techno jungang-daero, Hyeonpung-myeon, Dalseong-gun, Daegu 42988, Republic of Korea.
Abstract:
The dysregulation of dopamine, a neuromodulator, is associated with a broad spectrum of brain disorders, including Parkinson's disease, addiction, and schizophrenia. Quantitative measurements of dopamine are essential for understanding dopamine functional dynamics. Fast-scan cyclic voltammetry (FSCV) is the most popular electrochemical technique for measuring real-time in vivo dopamine level changes. Standard FSCV has only analyzed "phasic dopamine" (changes in seconds) because the gradual generation of background charging current is inevitable and is the primary noise source in the low-frequency band. Although "tonic dopamine" (changes in minutes to hours) is critical for understanding the dopamine system, an electrochemical technique capable of simultaneously measuring phasic and tonic dopamine in an in vivo environment has not been established. Several modified voltammetric techniques have been developed for measuring tonic dopamine; however, the sampling rates (0.1-0.05 Hz) are too low to be useful. Further investigation of the in vivo applicability of previously developed background drift removal methods for measuring tonic dopamine levels is required. We developed a second-derivative-based background removal (SDBR) method for simultaneously measuring phasic and tonic neurotransmitter levels in real-time. The performance of this technique was tested via in silico and in vitro tonic dopamine experiments. Furthermore, its applicability was tested in vivo. SDBR is a simple, robust, postprocessing technique that can extract tonic neurotransmitter levels from all FSCV data. As SDBR is calculated in individual-scan voltammogram units, it can be applied to any real-time closed-loop system that uses a neurotransmitter as a biomarker.
More Related Videos
07:41Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0
Published on: June 5, 2017
06:40Combined Infusion and Stimulation with Fast-Scan Cyclic Voltammetry CIS-FSCV to Assess Ventral Tegmental Area Receptor Regulation of Phasic Dopamine
Published on: April 23, 2020
Related Concept Videos
Voltammetric Techniques: Cyclic Voltammetry
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Pulse Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Factors Affecting Measurements
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...