Contactless Vital Signs Acquisition Using Video Photoplethysmography, Motion Analysis and Passive Infrared
Geoffrey A Capraro1, Benoit Balmaekers2, Albertus C den Brinker2
1Department of Emergency Medicine, Alpert Medical School of Brown University, Providence, Rhode Island.
Background:
Contactless vital signs (VS) measurement with video photoplethysmography (vPPG), motion analysis (MA), and passive infrared thermometry (pIR) has shown promise.
Objectives:
To compare conventional (contact-based) and experimental contactless VS measurement approaches for emergency department (ED) walk-in triage in pandemic conditions.
Methods:
Patients' heart rates (HR), respiratory rates (RR), and temperatures were measured with cardiorespiratory monitor and vPPG, manual count and MA, and contact thermometers and pIR, respectively.
Results:
There were 475 walk-in ED patients studied (95% of eligible). Subjects were 35.2 ± 20.8 years old (range 4 days‒95 years); 52% female, 0.2% transgender; had Fitzpatrick skin type of 2.3 ± 1.4 (range 1‒6), Emergency Severity Index of 3.0 ± 0.6 (range 2‒5), and contact temperature of 36.83°C (range 35.89-39.4°C) (98.3°F [96.6‒103°F]). Pediatric HR and RR data were excluded from analysis due to research challenges associated with pandemic workflow. For a 30-s, unprimed "Triage" window in 377 adult patients, vPPG-MA acquired 377 (100%) HR measurements featuring a mean difference with cardiorespiratory monitor HR of 5.9 ± 12.8 beats/min (R = 0.6833) and 252 (66.8%) RR measurements featuring a mean difference with manual RR of -0.4 ± 2.6 beats/min (R = 0.8128). Subjects' Emergency Severity Index components based on conventional VS and contactless VS matched for 83.8% (HR) and 89.3% (RR). Filtering out vPPG-MA measurements with low algorithmic confidence reduced VS acquired while improving correlation with conventional measurements. The mean difference between contact and pIR temperatures was 0.83 ± 0.67°C (range -1.16-3.5°C) (1.5 ± 1.2°F [range -2.1-6.3°F]); pIR fever detection improved with post hoc adjustment for mean bias.
Conclusion:
Contactless VS acquisition demonstrated good agreement with contact methods during adult walk-in ED patient triage in pandemic conditions; clinical applications will need further study.
More Related Videos
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...