Related Experiment Video
Updated: Sep 2, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Remotely Monitored Cardiac Implantable Electronic Device Data Predict All-Cause and Cardiovascular Unplanned
Camilla Sammut-Powell1, Joanne K Taylor1, Manish Motwani2,3
1Division of Informatics, Imaging and Data Sciences, Faculty of Biology, Medicine and Health University of Manchester, Manchester Academic Health Science Centre Manchester United Kingdom.
Abstract:
Background Unplanned hospitalizations are common in patients with cardiovascular disease. The "Triage Heart Failure Risk Status" (Triage-HFRS) algorithm in patients with cardiac implantable electronic devices uses data from up to 9 device-derived physiological parameters to stratify patients as low/medium/high risk of 30-day heart failure (HF) hospitalization, but its use to predict all-cause hospitalization has not been explored. We examined the association between Triage-HFRS and risk of all-cause, cardiovascular, or HF hospitalization. Methods and Results A prospective observational study of 435 adults (including patients with and without HF) with a Medtronic Triage-HFRS-enabled cardiac implantable electronic device (cardiac resynchronization therapy device, implantable cardioverter-defibrillator, or pacemaker). Cox proportional hazards models explored association between Triage-HFRS and time to hospitalization; a frailty term at the patient level accounted for repeated measures. A total of 274 of 435 patients (63.0%) transmitted ≥1 high HFRS transmission before or during the study period. The remaining 161 patients never transmitted a high HFRS. A total of 153 (32.9%) patients had ≥1 unplanned hospitalization during the study period, totaling 356 nonelective hospitalizations. A high HFRS conferred a 37.3% sensitivity and an 86.2% specificity for 30-day all-cause hospitalization; and for HF hospitalizations, these numbers were 62.5% and 85.6%, respectively. Compared with a low Triage-HFRS, a high HFRS conferred a 4.2 relative risk of 30-day all-cause hospitalization (8.5% versus 2.0%), a 5.0 relative risk of 30-day cardiovascular hospitalization (3.6% versus 0.7%), and a 7.7 relative risk of 30-day HF hospitalization (2.0% versus 0.3%). Conclusions In patients with cardiac implantable electronic devices, remotely monitored Triage-HFRS data discriminated between patients at high and low risk of all-cause hospitalization (cardiovascular or noncardiovascular) in real time.
More Related Videos
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Cardiomyopathy V: Interprofessional Care