Related Experiment Video
Updated: Sep 2, 2025

Evaluation of the Cognitive Performance of Hypertensive Patients with Silent Cerebrovascular Lesions
Published on: April 23, 2021
Excess pressure but not pulse wave velocity is associated with cognitive function impairment: a community-based study
Chen-Hua Lin1, Hao-Min Cheng1,2,3, Jiun-Jr Wang4
1Institute of Public Health.
Background:
Carotid-femoral pulse wave velocity (cf-PWV), an index of mainly distal aortic stiffness, has been inconsistently associated with cognitive function. Excess pressure, derived from the arterial reservoir-excess pressure analysis, may integrate the pulsatile load of the proximal aorta. The present study examined whether increased excess pressure is associated with cognitive function impairment in community adults.
Methods:
A total of 992 community participants (69.5% females; mean age: 67.3 years; education 13.6 years) without cerebrovascular disease or dementia received the Montreal Cognitive Assessment (MoCA) to evaluate global cognition. Arterial reservoir and excess pressure, arterial stiffness, and wave reflections were assessed, using carotid tonometry and aortic Doppler flowmetry.
Results:
Excess pressure integral (XSPI), percentage XSPI, cf-PWV, characteristic impedance (Zc), and forward and backward pressure amplitude (Pf, Pb, respectively) were significantly higher in 197 participants (19.9%) with a low MoCA score (<26 or <25, depending on level of education). In multivariable analyses, XSPI (standardized odds ratio, 95% confidence interval, 1.30, 1.06-1.59), and percentage XSPI (1.27, 1.06-1.52) but not cf-PWV (1.04, 0.85-1.26) were significantly associated with a low MoCA. Further analysis revealed that Pf and Zc were the major determinants of XSPI (partial R2: Pf = 0.656, Zc = 0.467) and percentage XSPI (Pf = 0.459, Zc = 0.371). In contrast, age, instead of Pf and Zc, was the major determinant of cf-PWV (partial R2: age = 0.187).
Conclusions:
Excess pressure (XSPI/percentage XSPI), mainly determined by the pulsatile hemodynamics of the proximal aorta, was significantly associated with cognitive function impairment in middle-aged and elderly community adults.
Related Concept Videos
Measurement of Blood Pressure
Blood Pressure
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Factors affecting Blood pressure
Physiological Factors:
Pulse
The pulse serves as a clinical...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.