Related Experiment Video
Updated: Sep 2, 2025

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Accuracy of Oxygen Saturation Measurements in Patients with Obesity Undergoing Bariatric Surgery
Yibo Xiong1,2, Guifeng Pan1, Weixin Huang1
1Department of Anesthesiology, The First Affiliated Hospital, Jinan University, No. 613, Huangpu Avenue West, Guangzhou, 510632, Guangdong, China.
Background:
We aimed to determine the magnitude, direction, and influencing factors of the concordance between arterial oxygen saturation (SaO2) and peripheral capillary oxygen saturation (SpO2) in patients with obesity undergoing bariatric surgery, supporting the measurement of SaO2 and SpO2 in key populations.
Methods:
Patients with obesity undergoing bariatric surgery from 2017 to 2020 were included. Preoperative SpO2 and SaO2 were collected. Linear correlation and multiple linear regression analyses were performed to characterize the relationships between body mass index (BMI), age, and sex with pulse oximetry and arterial blood gas (ABG) parameters. Bland-Altman analysis was applied to determine the concordance between SpO2 and SaO2 and the limits of this concordance.
Results:
A total of 134 patients with obesity undergoing bariatric surgery were enrolled. SaO2 was negatively associated with BMI (p < 0.0001) and age (p = 0.006), and SpO2 was negatively associated with BMI (p = 0.021) but not with age. SpO2 overestimated SaO2 in 91% of patients with a bias of 2.05%. This bias increased by 203% in hypoxemic patients compared with nonhypoxemic patients (p < 0.0001). The bias was 1.3-fold higher (p = 0.023) in patients with a high obesity surgery mortality risk score (OS-MRS) than in those with low or intermediate scores.
Conclusion:
Compared with SpO2, preoperative SaO2 can more accurately reflect the real oxygen saturation in patients with obesity undergoing bariatric surgery, especially for those with BMI ≥ 40 kg/m2, age ≥ 40 years, and high OS-MRS. ABG analysis can provide a more reliable basis for accurate and timely monitoring, ensuring the perioperative safety of susceptible patients.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:36Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...