Improved interassay correlation of digoxin results in patients with and without renal failure by elimination of
Use of immunoassays that do not detect endogenous digoxin-like immunoreactive factors (DLIF) in serum significantly improves the between-assay correlation of digoxin results for patients. We investigated five different immunoassay methods (Abbott, Clinical Assays, Corning, Du Pont, and Syva), measuring digoxin by all five assays in sera from 38 patients in renal failure and in 40 patients with normal renal function, all taking digoxin. The mean standard error of the estimate (Sy X x) of digoxin results (compared for all five assays) were significantly lower for patients with normal renal function than for patients in renal failure (0.148 vs 0.293 microgram/L, P less than 0.001). Assays previously shown (Clin Chem 1987;33:401) to be the least sensitive to DLIF (Syva and Corning) gave the lowest mean scatter about the regression (Sy X x = 0.192 microgram/L, renal failure; 0.114 microgram/L, normal renal function) for all 10 assay correlations. Evidently, discrepancies between digoxin values as measured by different immunoassay kits for patients with renal disease can be attributed to DLIF. Moreover, because inaccurate digoxin results attributed to DLIF may not be limited exclusively to groups of patients with known increased concentrations of DLIF, the possibility of "latent" DLIF interference may be a problem in many other human subjects.
Use of immunoassays that do not detect endogenous digoxin-like immunoreactive factors (DLIF) in serum significantly improves the between-assay correlation of digoxin results for patients. We investigated five different immunoassay methods (Abbott, Clinical Assays, Corning, Du Pont, and Syva), measuring digoxin by all five assays in sera from 38 patients in renal failure and in 40 patients with normal renal function, all taking digoxin. The mean standard error of the estimate (Sy X x) of digoxin results (compared for all five assays) were significantly lower for patients with normal renal function than for patients in renal failure (0.148 vs 0.293 microgram/L, P less than 0.001). Assays previously shown (Clin Chem 1987;33:401) to be the least sensitive to DLIF (Syva and Corning) gave the lowest mean scatter about the regression (Sy X x = 0.192 microgram/L, renal failure; 0.114 microgram/L, normal renal function) for all 10 assay correlations. Evidently, discrepancies between digoxin values as measured by different immunoassay kits for patients with renal disease can be attributed to DLIF. Moreover, because inaccurate digoxin results attributed to DLIF may not be limited exclusively to groups of patients with known increased concentrations of DLIF, the possibility of "latent" DLIF interference may be a problem in many other human subjects.
Related Concept Videos
Heart Failure Drugs: Inotropic Agents
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Drug Product Performance: In Vitro–In Vivo Correlation
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Excretion
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant