Related Experiment Video
Updated: Sep 2, 2025

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Supraglottic Airways Compared With Face Masks for Neonatal Resuscitation: A Systematic Review
Nicole K Yamada1, Christopher Jd McKinlay2,3, Bin Huey Quek4
1Division of Neonatal and Developmental Medicine, Department of Pediatrics, Stanford University School of Medicine, Palo Alto, California.
Background And Objectives:
Positive pressure ventilation (PPV) is the most important component of neonatal resuscitation, but face mask ventilation can be difficult. Compare supraglottic airway devices (SA) with face masks for term and late preterm infants receiving PPV immediately after birth.
Methods:
Data sources include Medline, Embase, Cochrane Databases, Database of Abstracts of Reviews of Effects, and Cumulative Index to Nursing and Allied Health Literature. Study selections include randomized, quasi-randomized, interrupted time series, controlled before-after, and cohort studies with English abstracts. Two authors independently extracted data and assessed risk of bias and certainty of evidence. The primary outcome was failure to improve with positive pressure ventilation. When appropriate, data were pooled using fixed effect models.
Results:
Meta-analysis of 6 randomized controlled trials (1823 newborn infants) showed that use of an SA decreased the probability of failure to improve with PPV (relative risk 0.24; 95% confidence interval 0.17 to 0.36; P <.001, moderate certainty) and endotracheal intubation (4 randomized controlled trials, 1689 newborn infants) in the delivery room (relative risk 0.34, 95% confidence interval 0.20 to 0.56; P <.001, low certainty). The duration of PPV and time until heart rate >100 beats per minute was shorter with the SA. There was no difference in the use of chest compressions or epinephrine during resuscitation. Certainty of evidence was low or very low for most outcomes.
Conclusions:
Among late preterm and term infants who require resuscitation after birth, ventilation may be more effective if delivered by SA rather than face mask and may reduce the need for endotracheal intubation.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...