Related Experiment Video
Updated: Sep 1, 2025

Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Left ventricular assist device implantation via lateral thoracotomy: A systematic review and meta-analysis
Roberto V P Ribeiro1, Jessica Lee1, Malak Elbatarny1
1Division of Cardiovascular Surgery, St. Michael's Hospital, Toronto, ON, Canada.
Background:
Left ventricular assist device (LVAD) implantation via lateral thoracotomy can offer similar effectiveness to conventional approaches with less perioperative adverse events. We performed a systematic review and meta-analysis to determine the potential benefits of lateral thoracotomy (LT) for LVAD implantation compared to median sternotomy.
Methods:
We searched MEDLINE and Embase databases for studies comparing continuous-flow LVAD implantation using LT with conventional sternotomy. Main outcomes were perioperative mortality and complications.
Results:
Twenty-five observational studies enrolling 3072 patients were included with a median follow-up of 10 months. Perioperative mortality (30 day or in-hospital) was 7% (LT) and 14% (sternotomy); however, mortality differences were no longer statistically significant in matched/adjusted studies (RR:0.86; 95%CI:0.52-1.44; p = 0.58). LT was associated with decreased need for blood product transfusions (mean difference[MD]: -4.7; 95%CI: -7.2 to -2.3 units; p < 0.001), reoperation for bleeding (RR:0.34; 95%CI:0.22-0.54; p < 0.001), postoperative RVAD implantation (RR:0.53; 95%CI:0.36-0.77; p < 0.001), days requiring inotropes (MD: -1.1; 95%CI: -2.1 to -0.03 inotrope days; p = 0.04), ICU (MD: -3.3; 95%CI: -6.0 to -0.7 ICU days; p = 0.01), and hospital length of stay (MD: -5.1; 95%CI: -10.1 to -0.1 hospital days; p = 0.04) in matched/adjusted studies. Overall mortality during follow-up was significantly lower for LT in unmatched/unadjusted studies but not statistically significantly lower in matched/adjusted studies (Hazard Ratio:0.82; 95%CI:0.59-1.14; p = 0.24).
Conclusion:
LVAD implantation via LT was associated with significantly decreased need for blood products, reoperation for bleeding, and postoperative RVAD implantation. Furthermore, days on inotropic support were also lower, likely contributing to the shorter length of stay. These findings support greater use of a LT approach for carefully selected patients.