Related Experiment Video
Updated: Sep 1, 2025

Development of a Rabbit Chronic-Like Rotator Cuff Injury Model for Study of Fibrosis and Muscular Fatty Degeneration
Published on: March 31, 2023
Novel therapy using a fish scale collagen scaffold for rotator cuff healing in rat models
Kohei Yamaura1, Yutaka Mifune1, Atsuyuki Inui1
1Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan.
Background:
Large and massive rotator cuff tears are challenging for surgeons because of postoperative complications such as repaired site retears. Recently, collagen extracted from fish scales has gained more attention because fish byproducts are considered a safer collagen source than other animal-derived scaffolds. This study aimed to evaluate the biological efficacy of tilapia scale-derived collagen scaffolds for rotator cuff repair in rat models.
Methods:
The infraspinatus tendon was resected from the greater tuberosity of Sprague-Dawley rats. In the control group, the tendon edge was sutured directly to the humeral head. In the augmentation group, the repaired site was augmented with a tilapia scale-derived collagen scaffold. Histologic examinations were performed at 2 and 4 weeks postoperatively via safranin O and immunofluorescence staining (isolectin B4 and type II collagen) in the bone-tendon junction. For mechanical analysis, the ultimate failure load of the tendon-humeral head complex was evaluated at 6 weeks postoperatively.
Results:
During safranin O staining, the repaired enthesis demonstrated greater proteoglycan staining in the augmentation group than in the control group at 4 weeks postoperatively. Compared to controls, the augmentation group had significantly higher vascular staining with isolectin B4 at 2 and 4 weeks postoperatively, type II collagen expression at 4 weeks postoperatively, and ultimate failure load at 6 weeks postoperatively.
Conclusion:
Augmentation therapy using tilapia scale-derived type I collagen scaffolds promoted angiogenesis and fibrocartilage regeneration at the enthesis and provided higher mechanical strength than controls.