Related Experiment Video
Updated: Sep 1, 2025

Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
Comparative Dose-Response Study on the Infusion of Norepinephrine Combined with Crystalloid Coload versus Colloid
Wei-Dong Jin1, Jun-Qin Mao2, Jie Liu2
1Department of Anesthesiology, Jinhua Maternity and Child Health Care Hospital, Jinhua, People's Republic of China.
Background:
Although the optimal infusion dose of norepinephrine combined with crystalloid coload for preventing spinal anesthesia-induced hypotension (SAIH) for cesarean delivery has been established, the infusion regimen of norepinephrine combined with colloid coload has not been fully quantified. The objective of this study was to compare and determine the median effective dose (ED50) and 90% effective dose (ED90) of norepinephrine infusion combined with crystalloid coload versus colloid coload for preventing SAIH during cesarean delivery.
Methods:
Two hundred parturients were randomly assigned to receive norepinephrine infusion at 0.02, 0.04, 0.06, 0.08, or 0.10 µg/kg/min in combination with 10 mL/kg crystalloid coload or colloid coload to prevent SAIH. The study period was defined as the interval from the commencement of intrathecal injection to delivery of the neonate. The primary outcome was non-occurrence of hypotension, defined as systolic blood pressure (SBP) less than 80% of the baseline before delivery. The ED50 and ED90 of norepinephrine infusion dose were determined using probit regression analysis. By calculating the 95% confidence intervals (CIs) of relative median potency to determine whether the prophylactic infusion of norepinephrine requirement was different between the two groups.
Results:
The derived ED50 and ED90 of norepinephrine infusion combined with crystalloid coload were 0.030 (95% CIs 0.020 to 0.038) and 0.097 (95% CIs 0.072 to 0.157) µg/kg/min, respectively. The ED50 and ED90 of norepinephrine infusion combined with colloid coload were 0.021 (95% CIs 0.013 to 0.029) and 0.070 (95% CIs 0.053 to 0.107) µg/kg/min, respectively. The estimate of relative median potency for norepinephrine between the two groups was 1.37 (95% CIs 0.94 to 2.23).
Conclusion:
Under the conditions of this study, 10 mL/kg colloid coload reduced the dose of prophylactic norepinephrine infusion by approximately 30% in parturients during spinal anesthesia for cesarean delivery compared with the crystalloid coload.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Cardiac Catheterization IV: Nursing Management
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Cardiopulmonary Resuscitation IV: Pharmacological Management

