Bacterial and fungal communities in indoor aerosols from two Kuwaiti hospitals

Nazima Habibi1, Saif Uddin1, Montaha Behbehani1

  • 1Environment and Life Science Research Centre, Kuwait Institute for Scientific Research, Kuwait City, Kuwait.

Insights

This study characterized indoor bioaerosols in Kuwaiti hospitals, revealing distinct bacterial and fungal populations compared to non-hospital settings. Findings emphasize the need for regular microbial surveillance in hospitals to prevent outbreaks and protect healthcare workers.

Area of Science:

  • Environmental Microbiology
  • Hospital Infection Control
  • Airborne Pathogen Surveillance

Background:

  • Airborne transmission of COVID-19 highlights the importance of bioaerosols in healthcare settings.
  • Understanding microbial communities in hospitals is crucial for preventing outbreaks and assessing occupational exposure risks for healthcare workers.
  • Indoor hospital environments pose risks due to the presence of diverse pathogenic and non-pathogenic microbes.

Purpose of the Study:

  • To establish a baseline of bacterial and fungal populations in the indoor air of two Kuwaiti hospitals treating COVID-19 patients and a non-hospital setting.
  • To compare microbial community structures between hospital and non-hospital environments.
  • To identify specific microbial taxa associated with hospital indoor air.

Main Methods:

  • Targeted amplicon sequencing was employed to analyze bacterial and fungal populations.
  • Samples were collected from two major hospitals in Kuwait and a non-hospital control site.
  • Statistical analyses, including Alpha-diversity indices, ANOSIM, and LefSe, were used to compare microbial communities.

Main Results:

  • Predominant bacteria included Variovorax, Parvibaculum, and Pseudonocardia; fungi were dominated by Wilcoxinia rehmii and Aspergillus ruber.
  • ESKAPEE pathogens were detected at lower abundances in hospital bioaerosols.
  • Hospitals exhibited lower alpha-diversity and distinct bacterial community structures compared to non-hospital sites, with specific taxa like Defluvicoccales and Heterophoma identified in hospitals.

Conclusions:

  • Indoor hospital bioaerosol composition differs significantly from non-hospital environments, with shifts in microbial communities indicated by the MD index.
  • Exhaled air contributes to inter-site variability in microbial populations.
  • Regular surveillance of indoor hospital environments is essential for preventing future outbreaks and ensuring healthcare worker safety.