A BRET Ca2+ sensor enables high-throughput screening in the presence of background fluorescence
Derrick Cumberbatch1, Tetsuya Mori1, Jie Yang1
1Department of Biological Sciences, Vanderbilt University, Nashville, TN, USA.
Abstract:
The intrinsic fluorescence of samples confounds the use of fluorescence-based sensors. This is of particular concern in high-throughput screening (HTS) applications using large chemical libraries containing intrinsically fluorescent compounds. To overcome this problem, we developed a bioluminescence resonance energy transfer (BRET) Ca2+ sensor, CalfluxCTN. We demonstrated that it reliably reported changes in intracellular Ca2+ concentrations evoked by an agonist and an antagonist of the human muscarinic acetylcholine receptor M1 (hM1R) even in the presence of the fluorescent compound fluorescein, which interfered with a standard fluorescent HTS sensor (Fluo-8). In an HTS using a chemical library containing fluorescent compounds, CalfluxCTN accurately identified agonists and antagonists that were missed or miscategorized using Fluo-8. Moreover, we showed that a luciferase substrate that becomes activated only when inside cells generated long-lasting BRET signals in HTS, enabling results to be reliably compared among replicate samples for hours. Thus, the use of a self-luminescent sensor instead of a fluorescent sensor could facilitate the complete screening of chemical libraries in a high-throughput context and enable analysis of autofluorescent samples in many different applications.