Related Experiment Video
Updated: Sep 1, 2025

Adjunctive Diode Laser Therapy and Probiotic Lactobacillus Therapy in the Treatment of Periodontitis and Peri-Implant Disease
Published on: May 9, 2022
Influence of irrigation and laser assisted root canal disinfection protocols on dislocation resistance of a
Ivona Bago1, Ana Sandrić2, Katarina Beljic-Ivanovic3
1Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gundulićeva 5, Zagreb 10000, Croatia.
Background:
It is not yet clear how different irrigation protocols and intracanal laser irradiation effects bioceramic sealers. In this vitro study, we aimed to evaluate the dislocation resistance of a bioceramic root canal sealer after different laser-assisted disinfection protocols and irrigants.
Methods:
Sixty extracted human straight single-canal teeth were instrumented, and randomly divided into five experimental groups (n=10) according to the disinfection protocol used: group 1, conventional needle irrigation (CI) with sodium hypochlorite (NaOCl)+ethylenediaminotetraacetic acid (EDTA)+NaOCl; group 2, Photon initiated photoacoustic streaming (PIPS) of NaOCl+EDTA+NaOCl; group 3, NaOCl+EDTA+diode laser; group 4, NaOCl+EDTA+photodynamic therapy (PDT); group 5, CI with NaOCl+EDTA+Chlorhexidine (CHX); and control group without any treatment. The root canals were filled with a bioceramic root canal sealer (BioRoot RCS) using the single-cone filling technique. After three weeks of storage, the samples from each canal thirds were transversely sectioned and the push-out test was performed.
Results:
The PIPS group showed the lowest dislocation resistance values in the coronal third (p>0.05), and no difference was observed among the other groups (p<0.05). The dislocation resistance in the middle and apical thirds was the highest in the diode laser group (p<0.05).
Conclusion:
Final root canal irradiation with diode laser led to improved dislocation resistance of the bioceramic sealer. PDT did not adversely affect the dislocation resistance of BioRoot RCS. The PIPS reduced the dislocation resistance values in the coronal third, but not in the middle and apical thirds.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:07Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024