Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Methods of Medium Optimization01:28

Methods of Medium Optimization

Optimizing growth media enhances microbial proliferation and maximizes product yield. Statistical experimental design methodologies provide structured and reproducible approaches, offering progressively higher levels of robustness and efficiency.The One-Factor-at-a-Time (OFAT) MethodThe One-Factor-at-a-Time (OFAT) method involves adjusting a single variable while keeping all others constant. However, it cannot detect interactions between variables, often leading to suboptimal outcomes when...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Animal camouflage: Sculpting with light.

Current biology : CB·2025
Same author

Advice on describing Bayesian analysis of neutron and X-ray reflectometry.

Journal of applied crystallography·2023
Same author

Quantifying the computational capability of a nanomagnetic reservoir computing platform with emergent magnetisation dynamics.

Nanotechnology·2022
Same author

Determining the maximum information gain and optimizing experimental design in neutron reflectometry using the Fisher information.

Journal of applied crystallography·2021
Same author

Dynamic environments do not appear to constrain spider web building behaviour.

Die Naturwissenschaften·2021
Same author

Object colours, material properties and animal signals.

The Journal of experimental biology·2019
Same journal

Quantitative analysis of light-induced ion segregation in mixed-halide perovskites.

Journal of applied crystallography·2026
Same journal

Towards machine-learning-based on-the-fly analysis of neutron reflectometry.

Journal of applied crystallography·2026
Same journal

<i>mcstas_gisans</i>: combining ray tracing with the distorted-wave Born approximation using <i>McStas</i> and <i>BornAgain</i> for virtual GISANS experiments.

Journal of applied crystallography·2026
Same journal

Computational methods for automated center determination in electron diffraction patterns.

Journal of applied crystallography·2026
Same journal

Epitaxy of ultrathin Fe<sub>3</sub>O<sub>4</sub> films on SrTiO<sub>3</sub>(001): influence of growth parameters on the formation of coexisting (111)- and (001)-oriented phases.

Journal of applied crystallography·2026
Same journal

Spin excitations near the pressure-induced antiferromagnetic transition in SrCu<sub>2</sub>(BO<sub>3</sub>)<sub>2</sub>.

Journal of applied crystallography·2026
See all related articles

Related Experiment Video

Updated: Jul 2, 2026

Using Neutron Spin Echo Resolved Grazing Incidence Scattering to Investigate Organic Solar Cell Materials
06:05

Using Neutron Spin Echo Resolved Grazing Incidence Scattering to Investigate Organic Solar Cell Materials

Published on: January 15, 2014

7.0K

Optimizing experimental design in neutron reflectometry.

James H Durant1, Lucas Wilkins2, Joshaniel F K Cooper1

  • 1ISIS Neutron and Muon Source, Science and Technology Facilities Council, Rutherford Appleton Laboratory, Didcot, Oxfordshire, OX11 0QX, United Kingdom.

Journal of Applied Crystallography
|August 17, 2022
PubMed
Summary
This summary is machine-generated.

Optimizing neutron reflectometry experiments with Fisher information (FI) enhances parameter confidence and experimental efficiency. This approach guides optimal measurement strategies for lipid systems and quantifies sensitivity for detecting small magnetic moments.

Keywords:
Fisher informationexperimental designinformation theoryneutron reflectivityneutron reflectometry

More Related Videos

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

2.4K
High-Resolution Neutron Spectroscopy to Study Picosecond-Nanosecond Dynamics of Proteins and Hydration Water
08:48

High-Resolution Neutron Spectroscopy to Study Picosecond-Nanosecond Dynamics of Proteins and Hydration Water

Published on: April 28, 2022

1.8K

Related Experiment Videos

Last Updated: Jul 2, 2026

Using Neutron Spin Echo Resolved Grazing Incidence Scattering to Investigate Organic Solar Cell Materials
06:05

Using Neutron Spin Echo Resolved Grazing Incidence Scattering to Investigate Organic Solar Cell Materials

Published on: January 15, 2014

7.0K
Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

2.4K
High-Resolution Neutron Spectroscopy to Study Picosecond-Nanosecond Dynamics of Proteins and Hydration Water
08:48

High-Resolution Neutron Spectroscopy to Study Picosecond-Nanosecond Dynamics of Proteins and Hydration Water

Published on: April 28, 2022

1.8K

Area of Science:

  • Materials Science
  • Neutron Scattering
  • Crystallography

Background:

  • Neutron reflectometry is a powerful technique for characterizing thin film interfaces.
  • Experimental design significantly impacts data quality and parameter extraction.

Purpose of the Study:

  • To optimize neutron reflectometry experiment design using Fisher information (FI).
  • To determine optimal measurement parameters for lipid bilayer systems.
  • To quantify the impact of underlayers and assess sensitivity for magnetic moment detection.

Main Methods:

  • Application of Fisher information (FI) for experimental design optimization.
  • Investigation of lipid bilayer systems with varying measurement angles and liquid contrasts.
  • Quantification of parameter uncertainty reduction using FI, validated by simulation and Bayesian sampling.
  • Analysis of 'one-shot' measurements for lipid monolayers.

Main Results:

  • Optimal measurement angles and liquid contrasts were identified for lipid bilayer systems.
  • Underlayers were shown to significantly reduce parameter uncertainties.
  • The study confirmed the optimality of measuring null-reflecting water for degrading monolayers, with angle dependence on deuteration.
  • Feasibility of detecting small magnetic moments (0.01 μB/atom) in thin layers (20 Å) was demonstrated.

Conclusions:

  • Fisher information provides a robust framework for optimizing neutron reflectometry experiments.
  • Informed experimental design enhances data reliability and efficiency for studying material interfaces.
  • The methodology enables precise characterization of thin films and detection of subtle magnetic properties.