Related Experiment Video
Updated: Sep 1, 2025

Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Early experience with coronary debulking devices in a newcomer facility after introducing revised facility criteria
Tetsuya Nomura1, Naotoshi Wada2, Issei Ota2
1Department of Cardiovascular Medicine, Kyoto Chubu Medical Center, 25, Yagi-Ueno, Yagi-cho, Nantan City, Kyoto, 629-0197, Japan. t2ya821@yahoo.co.jp.
Abstract:
Coronary debulking devices are essential in obtaining optimal results in percutaneous coronary intervention (PCI) for severely calcified lesions. However, since the introduction of these devices in Japan, the presence of full-time cardiovascular surgeons in their own facilities has been an essential condition (on-site surgical back-up) as the facility criteria for their use. The criteria were revised in April 2020, making their implementation possible at our hospital. Between May 2020 and January 2022, we administered PCIs using rotational atherectomy (RA) for 33 lesions in 28 patients and orbital atherectomy system (OAS) for 36 lesions in 27 patients. The most preferred strategy in our hospital is OAS via the distal radial approach using a 6Fr Glide sheath or RA via the femoral approach using a 7Fr sheath. The percentages of usable imaging modality as an initial device without lesion modification were 57.1 and 66.7% in the RA and OAS groups, respectively. In the RA procedure, 1.5- and 2.0-mm Rota burrs were more frequently adopted for the initial and second sessions, respectively. In the OAS procedure, the debulking was always initiated at a low speed. Nineteen of the 27 patients underwent additional high-speed debulking. Pre-procedural quantitative coronary angiographic analysis revealed that the minimal lumen diameter was significantly smaller in the RA than in the OAS group. Debulking procedures were successful in all patients excluding two instances of procedure-related complications in the RA group, one of which was coronary perforation safely treated via covered stent deployment without any resulting hemodynamic instability. Our early experience with coronary debulking devices with off-site surgical back-up clearly reveals the safety and feasibility of this procedure in a newcomer facility.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Coronary Artery Disease IV: Preventive Measures
Coronary Artery Disease I: Introduction
Acute Coronary Syndrome I: Introduction
Cardiac Catheterization I: Pre-Procedure Overview
Coronary Artery Disease V: Interprofessional Care

